Input connector and plug, Draft: brocade confidential – Brocade FastIron GS and GS-STK Hardware Installation Guide User Manual

Page 87

Advertising
background image

Brocade FastIron GS and GS-STK Hardware Installation Guide

77

53-1002186-02

Power supply specifications

6

DRAFT: BROCADE CONFIDENTIAL

Input connector and plug

Table 23

lists the input connectors for the power supplies.

FGS648 power drawn from outlet with 1 power supply
without uplink
with 2 CX4
with 2XFP
with Combo

162 W
170 W
170 W
170 W

FGS624 power drawn from outlet with 2 power supplies
(PS efficiency goes down as load increases)
without uplink
with 2CX4+1XFP
with 2XFP+1XFP
with Combo+1XFP

127 W
161 W
161 W
161 W

FGS648 power drawn from outlet with 2 power supplies
(PS efficiency goes down as load decreases)
without uplink
with 2 CX4
with 2XFP
with Combo

192 W
204 W
204 W
204 W

TABLE 22

Maximum Power Supply Consumption for FGS-STK Models

Model

Maximum Power
Consumption

FGS624-STK
with 2 CX4+1XFP

63 W

FGS648-STK
with 2 CX4

102 W

FGS624-STK power drawn from outlet with 1 power supply
with 2 CX4+1XFP

121 W

FGS648-STK power drawn from outlet with 1 power supply
with 2 CX4

170 W

FGS624-STK power drawn from outlet with 2 power supplies (PS
efficiency goes down as load increases)
with 2CX4+1XFP

161 W

FGS648-STK power drawn from outlet with 2 power supplies (PS
efficiency goes down as load decreases)
with 2 CX4

204 W

TABLE 21

Maximum Power Supply Consumption for FGS Models (Continued)

Model

Maximum Power
Consumption

Advertising