The TDM-series click counter has new hardware status codes. The terminal will display and log Errror

Code 123. It will then log the actual error in the click count. If there is a ‘116’ in the click count, there will

be a number immediately following that describes the error cause.
Ex: In the click history, you see ‘116’, followed by ‘18’. This indicates a hardware error caused by the
Extension Door Open.

Status

Code

Description

Double detect (0) not connected
Width sensor (0) not connected (Tx)
Width sensor (0) not connected (Rx)
Double detect (1) not connected
Width sensor (1) not connected (Tx)
Width sensor (1) not connected (Rx)
Double detect (2) not connected
Width sensor (2) not connected (Tx)
Width sensor (2) not connected (Rx)
Double detect (3) not connected
Width sensor (3) not connected (Tx)
Width sensor (3) not connected (Rx)

1
2
3
4
5
6
7
8

9

0

11
12

Diverter sensor not connected
Timing wheel sensor not connected
Exit sensor not connected
Reject sensor not connected
Extension sensor not connected
Extension door open
Extension main cable disconnected
12-volt supply low
12-volt supply high
24-volt supply low
24-volt supply high
Missing pick motor feedback
Missing solenoid feedback
Pick motor fuse blown
Transport motor fuse blown

13
14
15
16
17
18
19
20
21
22
23
24
25
26
27