Triton RL2000 User Manual User Manual

Page 90

Advertising
background image

111

Diverter timeout

Inspect for jammed currency at the diverter. Remove jammed
currency.
2. Verify that all access panels are closed and secured. Clear the
error. Test the dispenser by completing several test dispenses.
3. If the error clears, put the cash dispenser in service.
4. Verify clearance at the diverter. If the test dispenses pass, but
the error returns upon live dispenses, do dispenses with the vault
door open. If it works with the door open, remove obstruction
causing the diverter to contact the vault door.
5. If these actions have no effect on dispenser operation, replace
the dispenser mechanism.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

112

Timeout waiting for leading edge at
reject

A note that was expected to be seen at reject sensor was not
detected at the reject sensor.1. Inspect for jammed currency in the
transport path between the width sensors and the reject sensor.
Remove jammed currency. 2. Verify that all access panels are
closed and secured. Clear the error. Test the dispenser by
completing several test dispenses. 3. Verify clearance at the
diverter. If the test dispenses pass, but the error returns upon live
dispenses, do dispenses with the vault door open. If it works with
the door open, remove obstruction causing the diverter to contact
the vault door.4. If the error clears, put the cash dispenser in
service. 5. If these actions have no effect on dispenser operation,
replace the dispenser mechanism.Note: Dispenser Status (Click
Counts) should be run and available before contacting Tech Support

113

Timeout waiting for trailing edge at
reject

1. Inspect for a jammed currency in the reject sensor.
2. Verify that all access panels are closed and secured. Ensure the
reject bin is empty, or that there is enough room for the rejects and
test notes to fall into the reject bin. Reset the cash dispenser.
Clear the error. Test the dispenser by completing several test
dispenses.
3. If the error clears, put the cash dispenser in service.
4. If these actions have no effect on dispenser operation, replace
the dispenser mechanism.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

114

Exit blocked during purge

1. Inspect the dispensing mechanism for jammed currency at the
exit sensor. Clear any jammed currency.
2. Clean the exit sensor using a soft brush and a vacuum cleaner.
Reset the cash dispenser. Clear the error.
3. Test the dispenser by completing several test dispenses.
4. If the error clears, put the cash dispenser in service.
5. If these actions have no effect on dispenser operation, replace
the dispenser mechanism.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

115

Diverter timeout on purge

1. Inspect the dispensing mechanism for jammed currency at the
diverter. Clear any jammed currency.
2. Make sure the shelf that the dispenser is mounted on is level and
seated at all four corners.
3 Make sure the diverter moves freely.
4. Reset the cash dispenser. Clear the error.
5. Test the dispenser by completing several test dispenses. If the
error clears, put the cash dispenser in service.
6. If these actions have no effect on dispenser operation, replace
the dispenser mechanism.
Note: Dispenser Status (Click Counts) should be run and available
before contacting Tech Support

7

Advertising