The fifth line shows the Coefficient of Variation for the specific job.

Selecting “MORE” gives the user access to the second set of statistical data.

Selecting “DONE” returns the user to the storage menu screen.

NOTE:

The second set of calculations may require significant processing time, depending on
the number of readings stored in the specific job. The meter will display a screen with
the word “PROCESSING…” while calculations take place. User input is ignored during
this time. Control is returned to the user once the algorithm is complete and the second
statistics screen is shown, as in the example below:

The first line indicates the specific MC job.

The second line indicates the number of readings present in the specific job.

The third line shows the 95% Confidence Interval for the specific job. This is the

value (+/-) away from the calculated average value within which 95% of the

stored readings are guaranteed to exist.

The fourth line shows the value of the lowest MC reading stored in the specific

job.

The fifth line shows the value of the highest MC reading stored in the specific job.

There are no control entries present in this screen, such as “MORE”, “CANCEL” or
“DONE”. The only available option is to return to the storage menu screen, by pressing
any key.

STORED READINGS:

1. From the storage sub menu, use the



keys to highlight “STORED

READINGS.” Press the SELECT key to enter the stored readings sub menu.

There are two available selections from this menu, as follows: