MEASURING RH IN CONCRETE SLABS

:


When using the hygrometer feature, TotalCheck can be used to measure the RH in a
concrete slab in accordance with the ASTM F-2170-02 Standard Test Method for
Determining Relative Humidity in Concrete Floor Slabs.

Basic Test Procedure:

Drill 5/8-inch hole in concrete to the appropriate depth and remove debris from the

holes. Insert a CS-2 concrete sleeve into the hole and plug the sleeve with the cap
that is provided with each sleeve.

Wait approximately 72 hours.


Remove protective cap from the concrete sleeve and insert the RH/T-S1 humidity

sensor into the hole. Wait approximately 15 minutes to allow the sensor to acclimate
to the RH in the hole.

Connect one end of the RH/T-C1 cable to the top of meter and the other end to the

exposed end of the sensor. Take a RH reading using the RH/TEMP mode of
TotalCheck as described on pages 10 and 15. This reading is the RH of the concrete
slab.

For a complete explanation of the ASTM F2170-02 standard, please visit

www.ASTM.org

.


TESTING INSULATION

:

Set the meter scale

for the “REL 0-100” as described in the Create/Edit a Job

section on page 12.

To take a reading, attach a 21-

E electrode with 4” insulated contact pins to the

meter. Push the contact pins through the drywall into the insulation behind it.

Press the SELECT button and read the moisture content on the meter scale. The

meter displays the “relative” moisture level for two seconds.

To add a reading to the previously stored readings, release the SELECT button if

you are in triggered mode. If you are in continuous mode, the meter will not store a
new reading until the SELECT button is pressed and released again during the
reading cycle.


TESTING DRYWALL

Set the meter scale for

Sheetrock®

as described in the Create/Edit a Job section on

page 12.