Editing cr dynamic parameters – GW Instek PEL-2000 Series User Manual User Manual
Page 130

PEL-2000 Series User Manual
130
Panel Operation
1. Press F3 until Dynamic Range
mode is selected.
Note
Changing from static to dynamic mode will only affect
only the current (active) channel.
Editing CR Dynamic Parameters
CC levels
Dynamic Constant Resistance Mode has two
operating resistance Levels, slew rates and timers.
Slew rates determine the speed at which the load
will change from one level to the next.
The timers determine how long the load
module/channel will stay at level 1 or level 2. See
the CR operating description for details about slew
rates and timers, page 65
Ensure the menu is in CR Dynamic Mode. See page
129.
Parameters
Level1
Minimum ~ rating Ω
Level2
Minimum ~ rating Ω
SlewRate
Load module dependent
SlewRate
Timer1
0.025~30000.0ms
Timer2
0.025~30000.0ms