Edit sequence – GW Instek PEL-2000 Series User Manual User Manual
Page 151

OPERATION
151
Edit Sequence
Background
The Sequence function can be configured to create
a unique load profile to accurately simulate loads
in real time for single or multiple loads. For details
see page 74.
Each Sequence is composed of a number of points
with customizable current/resistance, slew rate
and duration times. Each sequence can be looped
an infinite amount of times. Sequences are only
applicable for CC (Static) and CR (Static) modes.
Parameters
Value 0~rating*1.02
Ω / A
SlewRate
Load module dependent
SlewRate
Duration Time 0.0001~60,000 seconds
Panel operation
1. Choose a channel and mode.
Page 119, 122
2. Press the CHAN key, F4 (Seq.
Edit) to enter the Sequence Edit
menu.
03/02/09
10 : 30
Configure
Add
Point
Loop
Delete
Point
CC
Static
High
CH1
Previous
Menu
s_edit