Managing the modules – modules, Net (shdsl), Menu – ADTRAN 600 Series User Manual

Page 49: Data rate, Frame mode, Annex a/b, Itu-991.2/gspan, Test, Network loopback, 0dqdjlqj wkh 0rgxohv ± 0rgxohv

Advertising
background image

Total Access 600 Series SHDSL IAD User Interface Guide/64200683L1-31B

Page 49

© 2002, ADTRAN, Inc.

Total Access 600 Series User Manual

Managing the Modules – Modules

Use the

0

2'8/(6

menu to view and set the parameters shown in Figure 17. The Total Access 600 contains four fixed

modules: The WAN/Network interface, FXS, Echo Canceller/ADPCM module, and the V.35 interface. The

0

2'



8/(6

table allows management of the on-board modules in the Total Access 600.

This menu contains

0

(18

,

$

/$50

,

7

(67

, and

6

7$786

indicators/menus customized for each module.

Figure 17. Modules Menu

>NET (SHDSL)

Menu

Data Rate

Used to select data rate of the network connection. (This should match the DSLAM settings.)

Frame Mode

Used to select either SDSL Framed (def) or SDSL Framed Plesiosynchronous with bit stuffing. (This
should match the DSLAM settings.)

Annex A/B

Used to select

$

11(;

$ $

11(;

% or both.

ITU-991.2/Gspan

Chooses between

,787  or *

/2%(63$1

9.

Test
These tests are meant for debug purposes only. A reboot may be required to return the Total Access 600 to
normal operation.

Network Loopback

Sets the network interface in loopback mode.