ELECTRICAL CONNECTIONS
4
49
OPTISONIC 3400
www.krohne.com
11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02
Control input active, modular I/Os
• U
int
= 24 VDC
• External contact open:
U
0, nom
= 22 V
External contact closed:
I
nom
= 4 mA
• Switching point for identifying "contact open or closed":
Contact open (off): U
0
≤ 10 V with I
nom
= 1.9 mA
Contact closed (on): U
0
≥ 12 V with I
nom
= 1.9 mA
• X designates the connection terminals A or B, depending on the version of the signal
converter.
Control input passive, modular I/Os
• 3 V ≤ U
ext
≤ 32 VDC
• I
max
= 9.5 mA at U
ext
≤ 24 V
I
max
= 9.5 mA at U
ext
≤ 32 V
• Switching point for identifying "contact open or closed":
Contact open (off): U
0
≤ 2.5 V with I
nom
= 1.9 mA
Contact closed (on): U
0
≥ 3 V with I
nom
= 1.9 mA
• X designates the connection terminals A or B, depending on the version of the signal
converter.
CAUTION!
Observe connection polarity.
Figure 4-20: Control input active C
a
1 Signal
Figure 4-21: Control input passive C
p