7.2.2 OPTIMASS 2000
The specified values are for guidance only.
• Driver = black and grey
• Sensor A = white and yellow
• Sensor B = green and violet
• Pt500 = red and blue (530…550 Ω) at ambient temperature
• Strain values measuring tube = 420...560 Ω
• Resistance values outside of the ranges specified above may indicate a circuit error. The
device may be in "start-up" mode or indicate measuring errors.
• All circuits should be isolated with respect to earth (device housing) and each other >20 MΩ.
• An exciter/sensor coil short circuit may cause the meter to be in "start-up" mode.
Size
Resistance (Ohm)
Driver
Sensor A/B
100
105
108
150
105
78
250
105
78
INFORMATION!
Failure of two or more of the upper circuits may indicate a measuring tube error. There may be
product in the housing. If this is the case, depressurise
depressurise
depressurise
depressurise the process line and immediately remove
the measuring device from the process line.