Ma/v module error messages – Martel Electronics 235 User Manual

Page 78

Advertising
background image

Unidentified err CalledBy ??????

An internal error has been detected by the calibrator firmware. Turn the
calibrator off and back on to reset the error. If the problem persists, note the
data in the lower right of the display and contact your service representative.

Wrong access code entered

You entered the wrong access code when attempting to change the owner’s
name or accessing the manufacturing test menu. The access code for changing
the owner name is found on the factory calibration sheet. The access code for
accessing the test menu is found in the BetaCal documentation for users who are
performing their own calibrations.

mA/V Module Error Messages


entered value is out of range

You may be attempting to output 1-10V without either activating the
module with the OPTION key or responding YES to the “use 10V
module?” prompt.

No input funct. For this module
The calibrator was in the input mode when the OPTION key was
pressed. The calibrator should be in the output mode before
attempting to activate this module.

Sensor?
The calibrator does not detect an internal or external temperature
compensation sensor. Check ECJ connection.