NSi Industries 8001 User Manual

Tork model 8001 duty cycle timer, Tork

Advertising
background image

TORK MODEL 8001

DUTY CYCLE TIMER

SWITCH: SPDT

CONTACT RATINGS:
20 AMP 120/240VAC
3/4HP 120VAC;
1-1/2HP 240VAC

TIMING MOTOR:
120VAC 60Hz

POWER CONSUMPTION:
3 WATTS MAX.

INSTALLATION AND OPERATING INSTRUCTIONS

TO SET OPERATING TIMES: Each dial tab represents approximately 15 min-
utes. These tabs can be tilted in and out with the fingers.

FOR OFF OPERATION: Tilt tabs outward as illustrated in
figure 1. Tilt out one tab for each fifteen minute period.
This closes load 2 and opens load 1.

Disconnect power at main panel prior to installing or servicing this
time switch or the equipment connected to it.
Connect in accordance with national and local electrical codes.
Supply Connections: Use gauge specified (AWG # 8-14) suitable for
75 degrees C (167 degrees F)

FOR ON OPERATION: Tilt tabs inward toward center of
dial, as illustrated in figure 2. This closes load 1 and
opens load 2.

TO SET DIAL TO TIME: Turn dial counter-clockwise until correct time is indicat-
ed by arrow on nameplate. Be sure to check whether time set is A.M. or P.M.

TO REMOVE MECHANISM FROM CASE: Press lever near case latch to
release mainplate and swing the movement out. To replace, insert mainplate pro-
jections in slots opposite latch and swing movement in until it latches.

TORK

®

1 GROVE STREET, MT. VERNON, NY 10550 TEL: 914-664-3542

FAX: 914-664-5052

LI-568(A)

H

120VAC

N

C

L

2

NO

NC

LOAD 2

MOTOR

LOAD 1

CLOSED WITH

TAB INWARD

CLOSED WITH

TAB OUTWARD

Fig. 2

Fig. 1