Alto-Shaam Combitherm 1008 User Manual

Page 130

Advertising
background image

C l e a n i n g a n d M a i n t e n a n c e

127.

E L E C T R I C M O D E L S

C l e a n i n g a n d M a i n t e n a n c e

D E C A L C I F I C A T I O N

ON BOILER EQUIPPED MODELS

u s i n g S c a l e F r e e ™ o r D i s t i l l e d W h i t e V i n e g a r

ScaleFree™

Descaling Compound is an acid-based descaler

combined with a proprietary chelating agent that is effective in dissolving and removing
carbonate, lime-scale and iron scale build-up caused by hard water. ScaleFree efficiently and
effectively removes lime-scale build-up from combi ovens.

ScaleFree™

is a non-hazardous, Biodegradable Citrus Based Powder that when mixed with

water becomes a powerful lime-scale remover.

It is VERY important to decalcify the oven, particularly in areas with extremely hard water.

PERFORM ONCE A MONTH in addition to the daily steam generator flush.

WITH THE OVEN AT ROOM TEMPERATURE

1.

Begin decalcification with the power
key in the OFF position.

2.

Open oven door. Rotate the Steam
Generator Drain Cap

until water

begins to flow from the four holes in
the cap. In approximately 20 to 60
seconds, a sufficient quantity of water
will have drained from the steam
generator so that the drain cap can be
completely removed.

3.

Let the water continue to drain until
the flow completely subsides. Replace
the Steam Generator Drain Cap

by

turning it clockwise until there is a
slight resistance. Close oven door.

4.

Using the batch mix instructions on
the label, mix up 1 gallon of
ScaleFree™

solution at a time or

one gallon of distilled white vinegar
for counter top models and 3 gallons
of distilled white vinegar for floor
standing models. Using a funnel inserted
into the Steam Relief Valve

, slowly pour

solution in to the Steam Generator until full.

5.

Remove funnel from Steam Relief Valve

.

PRESS THE ON/OFF POWER KEY
TO THE ON
POSITION.

The unit will add water if needed.

PRESS THE STEAM PROGRAM KEY
The unit will begin to pre-heat.

DO NOT PRESS START.

(Continued on next page)

DURING DECALCIFICATION THE WATER FLOWING
FROM THE DRAIN CAP IS EXTREMELY HOT! USE
HAND PROTECTION WHEN TOUCHING THE STEAM
G E N E R AT O R D R A I N C A P. D O N O T T O U C H T H E
WATER FLOWING OUT OF THE STEAM GENERATOR
DRAIN CAP OR STEAM GENERATOR DRAIN.

S

T

A

N

D

A

R

D

C

O

N

T

R

O

L

D

E

L

U

X

E

C

O

N

T

R

O

L

STANDARD CONTROL

DELUXE CONTROL

STEAM RELIEF VALVE

STEAM
BYPASS
PORT

STEAM EXIT
PORT

OVEN LIGHT

FAN

FAN GUARD
COVER PLATE

STEAM
GENERATOR
DRAIN CAP

OVEN DRAIN

Advertising