Connecting example 6, Electrical connections – West Control Solutions TB 40-1 Temperature Limiter User Manual

Page 6

Advertising
background image

Connection of output OUT LC

4

Relay (250V/2A), potential-free changeover contact

Connection of outputs OUT1/2

5

Relay outputs 250V/2A normally open with common contact connection

a

The pre-alarms (OUT1/2) must be used only for signalling and not for control
purposes!

a

The pre-alarm OUT2 is available only if configured as TW!

TB40-1 connecting example:

a

CAUTION:

Using a temperature limiter is recommendable in systems where overtemperature
implies a fire hazard or other risks.

Electrical connections

Connecting diagram TB 40-1 temperature limiter TB

6

TB40-1

1

2

3

4

7

5

8

6

9

10

11

12

13

14

15

Logic

+

_

L1

L2

N1

N2

fuse

1

2

3

4

7

5

8

6

9

10

11

12

13

14

15

TB 40-1

Temperature limiter

1

KS 40-1

SSR

reset

contactor

heating

1 TB 40-1 Temperature limiter

Standard version (2 relays):
TB40-102-0000D-000

other versions on request

r

+

+

fuse

fuse

Advertising