PROGRAMMING

The monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode Both the RUN mode and the

PROGRAM mode display screen enunciators confirm the state of the monitor A quick glance at the lower left-hand corner of

the LCD screen will confirm operating status Normal operation will be in the RUN mode To access the PROGRAM mode, press

MENU until the first programming screen is displayed After programming the display with the necessary information, a lock

out feature can be turned on to prevent unauthorized access or changing the meter’s setup parameters

BASIC PROGRAMMING MODE

Keys

MENU – Switches to PROGRAM mode
UP Arrow – Scrolls through the parameter choices in forward direction and increments numeric variables
RIGHT Arrow – Scrolls through the parameter choices in reverse direction and moves the active digit to the right
ENTER – Used to save programming information, advance to the next programming parameter and in the reset process

Modes

RUN – Normal operating mode
PROGRAM – Used to program variables into the display

If your monitor was ordered with a Blancett flow meter, the two components ship from the factory calibrated as a set If the

monitor is a replacement, the turbine’s K factor has changed or the monitor is being used with some other pulse generating

device, programming will be necessary

PROGRAMMING USING PULSE OUTPUT TURBINE FLOW METERS

Each turbine flow meter is shipped with either a K factor value or frequency data If frequency data is provided, the data must

be converted to a K factor before programming the monitor K factor information, when supplied, can usually be found on the

neck of the flow meter or stamped on the flow meter body The K factor represents the number of pulses per unit of volume

The K factor will be needed to program the monitor readout

Enter Programming Mode

Change to PROGRAM mode by pressing MENU The mode indicator will change from RUN to PROGRAM

OTEE:

N

If any input value exceeds the meter’s capabilities for that particular parameter, the LIMIT indicator will begin to flash

indicating an invalid entry Press ENTER to return to the parameter’s entry screen to re-enter the value