Reset Password

Reset password protection prevents unauthorized users from manually resetting the flow monitor’s accumulated totals

Initially, the password is set to all zeros To change the reset password, simply enter any four digit code using the arrows as

previously described to enter the password value Pressing ENTER will store the reset password

OTEE:

N

Entering a password in the PASSWORD screen and leaving the password blank in the RST PSWD screen would allow

for total resets (not requiring password) and restrict programming modification

Reset Total

To reset the monitor’s total display, in RUN mode press MENU and ENTER simultaneously until TOTAL RST starts to flash The

TOTAL RST will stop flashing and the display will return to RUN mode at the conclusion of the procedure

Store Total

The current total can be manually stored in the monitor’s flash memory This procedure may be desirable prior to changing

the settings or replacing the battery Press and hold ENTER for two seconds The display will respond with a flashing

TOTALSVD and then return to RUN mode

Automatic Store Total

The monitor is equipped with a store total feature that works automatically, saving the current total to flash memory The

frequency of saves depends on the power supply option chosen

Battery Powered

Once per hour and just before a low battery condition turns the unit off

Loop Powered

Once every ten minutes

ADDITIONAL INPUT OPTIONS

The Blancett flow monitor is capable of receiving magnetic pickup input or a contact closure input Since most Blancett flow

meters utilize a magnetic pickup, the monitor is shipped configured for magnetic pickup input To change to a contact closure

input, remove JP2 from the bottom two pins and jumper them to the top two pins See

Figure 4

BATTERY REPLACEMENT

Battery powered monitors use a single 1 5V, D size alkaline battery When replacement is necessary, use a clean fresh battery

to ensure continued trouble-free operation It is recommended that the total be saved to memory before the battery

is removed

DO NOT OPEN EXPLOSION PROOF ENCLOSURE UNLESS THE AREA IS KNOWN TO BE FREE OF HAZARDS. FAILURE

TO MAKE THE AREA SAFE BEFORE OPENING THE ENCLOSURE CAN RESULT IN A HAZARDOUS SITUATION WITH A

POTENTIAL FOR INJURY.
Carefully unscrew the enclosure cover to access the circuit board Remove the four screws securing the circuit board to

the enclosure Lay the circuit board to the side being careful not to pull any wires from their connections Clip the battery

retaining wire/strap and remove the battery Replace the battery, being sure to observe the proper polarity and install a new

retaining strap or wire Reassemble the monitor, reversing the disassembly process