Iii. specifications – Badger Meter Turbine Flow Meters (Hydraulic Fluids) User Manual

Page 6

Advertising
background image

Turbine Flow Sensor

Installation & Operating Instructions

Page 6

03/12 Form No. 05-TUR-UM-00194

III. SPECIFICATIONS

Activa™ and Ultima Sensor Arrays

Material

Housing:

6013-T651 Anodized aluminum

Turbine Rotor:

T416 Stainless steel

Rotor Supports:

6061-T6 Aluminum,

C360 Brass for ¼" models

Rotor Shaft:

T303 Stainless steel

Ball Bearings:

440 C Stainless steel

Hub Cones:

6061-T6 Aluminum alloy

Retaining Rings:

6061-T6 Aluminum alloy

Adapters/Plugs:

6061-T6 Anodized aluminum

Seals:

Buna N standard

Viton® and EPR optional

Magnetic Pick-up:

Body

T303 Stainless Steel

Nut

T303 Stainless Steel

IFC (Intelligent Frequency Converter), Activa only:

Body

6061-T6 Aluminum, nickel plate

Connector

Brass, nickel plate

Temperature Probe:

12L14 Steel, electroless nickel finish

Pressure Sensor:

Case

300 Series stainless steel

Diaphragm

17-4 PH stainless steel

Ports:

SAE Straight thread O-ring boss, female, J1926/1;

ISO1179 (BSPP)

Dimensions

See Appendix, page 16

Model Number Information

Performance

Flow Accuracy:

Activa

±1% of reading @ 32 cSt

Ultima

±1% of full scale

Repeatability: ±0.2%

Pressure Rating:

5800 PSI (400 Bar) maximum,

5000 PSI (345 Bar) maximum for 1-¼" models

Pressure Drop:

See ∆ P charts on page 17

Turbine Response:

≤200 ms

Fluid Temperature:

-4 to +300 °F (-20 to +150 °C)

Ambient Temperature:

-4 to +131 °F (-20 to +55 °C)

Electrical

Activa

4-20 mA

0-5 VDC

Power:

Loop-powered, 6V

10-26 VDC

insertion loss max

10-30 VDC supply

Inputs:

Mag pick-up

Mag pick-up

Frequency

0-3500 Hz

0-3500 Hz

Trigger

Sensitivity

30 mV p-p

30 mV p-p

Freq Meas Accuracy

±1%

±1%

Analog Out:

4-20 mA current loop

0-5 VDC

Resolution

1:4000

1:4000

Temp Drift

50 ppm/°C max

50 ppm/°C max

Environmental:

Ambient Temp

-22 to +158 °F

-22 to +158 °F

(-30 to +70 °C)

(-30 to +70 °C)

Humidity

0-90%

0-90%

non-condensing non-condensing

Ultima

Magnetic Pick-up:

Self-generating alternating pulse;

100 mV RMS (100 Hz) minimum.

F6202 & F6222 only

10 mV RMS (200Hz) minimum

Calibration

Flow sensors are calibrated with 0.876 specific gravity, 140

SUS (32 cSt) hydraulic oil. Standard calibration is done using

3-points and is traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-

STD 45662A.

Nominal

Port Size

Flow Rate

Model

IFC Converter

or Mag Pick-up

Seals

Sensor Ports

Temperature

Pressure

SAE 8

0.4 - 7 GPM

F6202

Activa Models:

AI 4-20 mA Out

AV 0-5 VDC Out

Ultima Models:

F Frequency Out

B Buna N

V Viton

E EPR

T with Sensor

N ¼ NPT(F)

Plugged

S SAE 2 Plugged

G G ¼ Plugged

D SAE 4 Plugged

1 1000 PSI

3 3000 PSI

5 5000 PSI

6 6000 PSI *

N ¼ NPT(F)

Plugged

S SAE 2 Plugged
F G ¼ Plugged

* Not available with

Models F6208 or F6228

SAE 12

2 - 40 GPM

F6204

SAE 16

4 - 80 GPM

F6206

SAE 20

8 - 160 GPM

F6208

G ¼

1.5 - 26 LPM

F6222

G ¾

7.5 - 151 LPM

F6224

G 1

15 - 302 LPM

F6226

G 1-¼

30 - 605 LPM

F6228

Examples:

F6204-AIB-T6

= SAE 12 ports, 2-40 GPM flow range

Buna N seals, Temperature sensor

6000 PSI (414 Bar) pressure sensor

F6208-FV-TN

= SAE 20 ports, 8-160 GPM flow range

Viton seals, Temperature sensor

1/4 NPT (F) plugged pressure port

Advertising