IV. INSTALLATION

CAUTION

This product should be installed and serviced by technically qualified personnel trained in maintaining

industrial class flow instrumentation and processing equipment.

CAUTION

Read instructions thoroughly before installing the flow sensor. If you have any questions regarding

product installation or maintenance, call your local supplier or the factory for more information.

WARNING

Do not use male pipe threads (NPT) into SAE straight thread ports. Using male pipe threads (NPTF) with

a flow sensor possessing SAE straight thread O-ring ports will not create a proper seal and is potentially

dangerous. Pipe threads inserted into an SAE straight thread port only allow the engagement of one

or two threads. No amount of tightening or thread seal will stop the leaking or make the installation

safe. Failure to follow these instructions could result in serious personal injury or death and/or damage

to the equipment.

Installation Recommendations

The in-line flow sensor is a simple device to install. However, the following measures are recommended for

reliable, trouble-free operation:

DO - Provide at least 10 port diameters of upstream straight pipe with no obstructions to the flow sensor

and at least 5 diameters of downstream pipe. The pipe should be of the same diameter as the nominal

port size.
Example:

An FSC-1000 has a one inch (25.4 mm) port. The unobstructed upstream length should be at least 10

inches (254 mm) and the downstream length should be at least 5 inches (127 mm).

FIGURE 1

Upstream and Downstream Pipe Diameters

1" PORT

(25.4 mm)

END VIEW

5 PORT DIAMETERS

5" (127 mm)

10 PORT DIAMETERS

10" (254 mm)

IN