Badger Meter Turbine Flow Meters (Hydraulic Fluids) User Manual

Page 7

Advertising
background image

Turbine Flow Sensor

Installation & Operating Instructions

03/12 Form No. 05-TUR-UM-00194

Page 7

Classic Flow Sensors

Material

Housing:

FSC, FSB

6013-T651 Anodized aluminum

FSD

Stressproof® steel, zinc plated

Turbine Rotor:

T416 Stainless steel

Rotor Supports:

FSC-375, 500, 750

C360 Brass

FSC-1000, 1005

6061-T6 Aluminum

FSD

Tungsten carbide

Rotor Shaft:

FSC, FSB

T303 Stainless steel

FSD

Tungsten carbide

Bearings:

FSC, FSB

440 C Stainless steel ball bearings

FSD

Tungsten carbide

Hub Cones:

FSC, FSB

6061-T6 Aluminum alloy

Retaining Rings:

FSC

T303 Stainless steel

FSC-500, 750, 1000, 1005;

FSB; FSD

Steel, zinc plate

Adapters/Plugs:

6061-T6 Anodized aluminum

Seals:

Buna N standard

Viton® and EPR optional

Magnetic Pick-up:

Body

T303 Stainless Steel

Nut

T303 Stainless Steel

IFC (Intelligent Frequency Converter):

Body

6061-T6 Aluminum, nickel plate

Connector

Brass, nickel plate

Ports:

SAE Straight thread O-ring boss, female, J1926/1;

Code 61 and Code 62: SAE J518

Dimensions

See Appendix, page 16

Model Number Information

Performance

Flow Accuracy:

Standard Magnetic Pick-up

±1% of full scale

IFC Converter Option

±1% of reading @ 32 cSt

Repeatability: ±0.2%

Pressure Rating:

FSC, FSB

5000 PSI (345 Bar) maximum,

FSD

6000 PSI (414 Bar) maximum

Pressure Drop:

See ∆ P charts on page 17

Turbine Response:

≤200 ms

Fluid Temperature:

-4 to +300 °F (-20 to +150 °C)

Ambient Temperature:

-4 to +131 °F (-20 to +55 °C)

Electrical

Magnetic Pick-up:

Self-generating alternating pulse;

100 mV RMS (100 Hz) minimum.

FSC-375 only

10 mV RMS (200 Hz) minimum

IFC Converter:

4-20 mA

0-5 VDC

Power:

Loop-powered, 6V

10-26 VDC

insertion loss max

10-30 VDC supply

Inputs:

Mag pick-up

Mag pick-up

Frequency

0-3500 Hz

0-3500 Hz

Trigger

Sensitivity

30 mV p-p

30 mV p-p

Freq Meas Accuracy

±1%

±1%

Analog Out:

4-20 mA current loop

0-5 VDC

Resolution

1:4000

1:4000

Temp Drift

50 ppm/°C max

50 ppm/°C max

Environmental:

Ambient Temp

-22 to +158 °F

-22 to +158 °F

(-30 to +70 °C)

(-30 to +70 °C)

Humidity

0-90%

0-90%

non-condensing non-condensing

Calibration

Flow sensors are calibrated with 0.876 specific gravity, 140

SUS (32 cSt) hydraulic oil. Standard calibration is done using

3-points and is traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-

STD 45662A.

Nominal

Port Size

Flow Rate

Series

Model

with Frequency Out

Model

with 4 - 20 mA Out

Model

with 0 - 5 Vdc Out

SAE 8

0.4 - 7 GPM

FSC-375

F2945-ASCM

F2945-ASCI

F2945-ASCV

SAE 12

1 - 15 GPM

FSC-500

F2082-ASCM

F2082-ASCI

F2082-ASCV

SAE 12

2 - 25 GPM

FSC-750

F2083-ASCM

F2083-ASCI

F2083-ASCV

SAE 16

3 - 60 GPM

FSC-1000

F2084-ASCM

F2084-ASCI

F2084-ASCV

SAE 16

4 - 85 GPM

FSC-1005

F2084-ASCM8

F2084-ASCI8

F2084-ASCV8

SAE 20, Code 61

5 - 100 GPM

FSB-1250

F2085-ASBM

F2085-ASBI

F2085-ASBV

SAE 24, Code 61

7 - 200 GPM

FSB-1500

F2086-ASBM

F2086-ASBI

F2086-ASBV

SAE 20, Code 62

5 - 100 GPM

FSD-1250

F2085-SCDM

F2085-SCDI

F2085-SCDV

SAE 24, Code 62

7 - 200 GPM

FSD-1500

F2086-SDCM

F2086-SCDI

F2086-SCDV

SAE 32, Code 62

10 - 350 GPM

FSD-2000

F2998-SCDM

F2998-SCDI

F2998-SCDV

Advertising