Series 3050 Btu Monitor

USB COMMAND LIST

In the list below, brackets indicate an argument, specifying

its type and value range. For instance [0-18] stands for any
number between 0 and 18 (inclusive).

Example: “display line1 = 1” sets Line 1 of the display to display
#1, which happens to be the totalizer for flow channel 1.

Diagnostics:

id – show model number & software version

echo [on/off] – turn on/off interactive command line:

with echo off, this interface is more

amenable to scripting; it still accepts the

same commands.

Any command entered without an “ = “ sign and

variable will display the current setting.

Example: Typing “display line1” returns “0” which is the

variable for Flow rate.

read flow [1-2] – read the current flow on channel 1 or 2

in GPM.

read flow [1-2] total – read the current total flow on

channel 1 or 2 in gallons.

DISPLAY CONFIGURATION

display line1 = [0-18] – set line 1 of the display

display line2 = [0-18] – set line 2 of the display

valid options are:

0: flow 1 rate

1: flow 1 total

2: flow 2 rate

3: flow 2 total

4: flow 1+2 rate

5: flow 1+2 total

6: flow 1-2 rate

7: flow 1-2 total

8: flow 2-1 rate

9: flow 2-1 total

14: BTU rate

15: BTU total

16: temperature 1&2

17: temperature 1-2

display urate = [0.1-10] – set the update rate of the display, in

seconds

FLOW INPUT CHANNEL CONFIGURATION

flow [1-2] sensor type = [0-4] – flow sensor type:

0: PulseDI,

1: PulseKFactor,

2: PullupKFactor

3: Analog

flow [1-2] sensor dical k = [x] – DI-type flow sensor k

flow [1-2] sensor dical off = [x] – DI-type flow sensor offset

flow [1-2] sensor kfact = [x] – K factor for non-DI sensors

flow [1-2] sensor analog units = [0-19] – flow units for analog

input

flow [1-2] sensor analog range = [0-4] – current range for

analog input

flow [1-2] sensor analog high = [x] – flow rate @max current

flow [1-2] sensor analog low = [x] – flow rate @min current

flow [1-2] sensor avg = [0-100] – averaging "time constant," in

seconds:

flow [1-2] rate units = [0-19] – flow (channel) rate units to

display.

0: GPM

1: gal/s

2: gal/hr

3: Mgal/day

4: L/s

5: LPM

6: L/hr

7: ft3/s

8: ft3/min

9: ft3/hr

10: m3/s

11: m3/min

12: m3/hr

13: acreft/s

14: acreft/min

15: acreft/hr

16: bbl/s

17: bbl/min

18: bbl/hr

19: Custom

flow [1-2] rate ndigits = [2-10] – number of decimal places to

show for flow rate

flow [1-2] rate custom label = [string] – set the label for custom

units

flow [1-2] rate custom conv = [0-100] – conversion factor for

custom units

flow [1-2] total units = [0-7] – set the totalizer units to display

0: gal

1: Mgal

2: L

3: ft3

4: m3

5: acreft

6: bbl

7: Custom