Badger Meter SRD/SRI Valve Positioners User Manual

Page 17

Advertising
background image

1)

Operating mode min. (= Low) / max. (= high)
selectable by adjustment of switch vanes

2)

Data measured according to VDI/VDE 2177

3)

With stroke 30 mm and lever length 90 mm

4)

Operating mode normally open / normally closed selectable
by vane adjustment

5)

Approval according to UL (UL 1054) and CSA (CSA 22.2
No. 55) at 6,000 operations and T = 65 °C / 149 °F

6)

Based on EN 61058-1, at 10,000 operations and T = 85 °C

7)

General rating at 50,000 operations and T = 85 °C / 185 °F

ADDITIONAL EQUIPMENT

(continued)

Additional Inputs/Outputs built into any SRD960 -B or C

Order in Model Code: SRD960–

T, U, R, V

Built-in Limit Switch

[item

2

]

Inductive Limit Switch

standard version (SJ2-N) . . . . . . Code T
security version (SJ2-SN). . . . . . Code U
- in three wire technology

(SI 2-K08-AP7). . . . . . . . . . . . . Code R

Stroke / angle derivated from positioner feedback,
two-wire system
Output . . . . . . . . . . . . . . . . . 2 inductive proximity sen-

sors acc. to DIN 19 234 or NAMUR for connection to

switching amplifier with intrinsically safe control circuit

1)

Current consumption

vane clear . . . . . . . . . . . . . > 2.2 mA
vane interposed . . . . . . . . . < 1 mA

for control circuit with the following electrical values

supply voltage . . . . . . . . . . DC 8 V, R

i

approx. 1 kOhm

supply voltage range . . . . . DC 5...25 V (only with ZZZ)
residual ripple . . . . . . . . . . < 10 % p.p.
permissible
line resistance . . . . . . . . . . < 100 Ohms

Response characteristic

2) 3)

switching differential. . . . . . < 1 %
switching point repeatability < 0.2 %

Terminals for Code T, U . . . GW1 . 41+, 42–

GW2 . 53+, 54–

Terminals for Code R . . . . . . GW1 . 42

GW2 . 52

Supply 41+, 43–

Explosion protection thereto see “PHYSICAL
SPECIFICATIONS.”
Parts sets for subsequent mounting:
Code T . . . . . . . . . . . . . . . . EW 426 346 057
Code U . . . . . . . . . . . . . . . . EW 426 346 066
Code R . . . . . . . . . . . . . . . . EW 426 346 075

Built-in Limit Switch

[item

2

]

Mechanical switches

Micro Switches. . . . . . . . . . . Code V

Stroke / angle derivated from positioner feedback lever

Output . . . . . . . . . . . . . . . . . 2 mechanical switches

(Micro switches)

1) 4)

Manufacturer . . . . . . . . . . . . Saia-Burgess
Type . . . . . . . . . . . . . . . . . . V4NS-C4-AC1-UL

UL- and CSA-approved

Absolute limit values

AC

of mechanical switches built into positioner:
Umax. . . . . . . . . . . . . . . . . . 42 V AC

5)

Imax . . . . . . . . . . . . . . . . . . 0.5 A (resistive load)

5)

Imax . . . . . . . . . . . . . . . . . . 0.03 A (inductive load)

6)

Absolute limit values

DC

of mechanical switches built into positioner:

7)

Umax. . . . . . . . . . . . . . . . . . 30 V DC
Imax . . . . . . . . . . . . . . . . . . 1 A

Switching Differential:. . . . . . < 2.5 %
Terminals for SW1 . . . . . . . . 41, 42

SW2. . . . . . . . 51, 52

The circuit of the mechanical switches have to be protected

by a suitable fuse. The diameter of the protective conductor

needs to be at least 1.5 mm² / AWG 16.

Parts set for subsequent mounting
Code V . . . . . . . . . . . . . . . . EW 426 346 084

POS-UM-00012-EN-02

Additional Equipment