FUNCTIONAL SPECIFICATIONS (COMMON DATA FOR SRD960-B OR -C)

Air output ln/h (scfh)

at max. deviation, single and double acting:

Supply air
pressure
bar (psig)

1.4

(20)

3

(45)

6

(90)

without
booster

5)

2 700

(95)

5 000

(177)

7 500

(265)

with
Spool
Valve

4)

6 000

(211)

12 000

(423)

18 000

(636)

with
booster
code F, G

21 000

(742)

with
booster
code H

42 000

(1 484)

Note: The use of boosters in connection with Spool valve

is not recommended.

Travel range

Stroke range . . . . . . . . . . . . 8 ... 260 mm (0.3 ... 10.2 in)

with standard feedback levers; special levers on request

Rotation angle range . . . . . . up to 95 °

(without mechanical stop)

Supply

Supply air pressure

5)

. . . . . . 1.4 ... 6 bar (20 ... 90 psig)

with spool valve

4)

. . . . . . 1.4 ... 7 bar (20 ... 105 psig)

Output to actuator . . . . . . . . 0 to ~100 % of supply air

pressure (up to 5.5 bar at

6 bar supply air pressure)

Air supply

1)

. . . . . . . . . . . . . according to ISO 8573-1

Solid particle size and density class 2
Oil rate . . . . . . . . . . . . . . . . class 3
Pressure dew point 10 K under ambient temperature
For air supply, we recommend the FOXBORO ECKARDT
FRS923 filter regulator.

Response characteristic

2) 3)

Sensitivity . . . . . . . . . . . . . . < 0.1 % of travel span
Non-linearity (terminal
based adjustment) . . . . . . . . < 0.4 % of travel span
Hysteresis . . . . . . . . . . . . . . < 0.3 % of travel span
Supply air dependence. . . . . < 0.1 % / 1 bar (15 psi)
Temperature effect. . . . . . . . < 0.3 % / 10 K
Mechanical vibration
10 to 60 Hz up to 0.14 mm,
60 to 500 Hz up to 2 g . . . . . < 0.25 % of travel span

1)

Pressure dew point 10 K under ambient temperature

2)

Data measured according to VDI/VDE 2177

3)

With stroke 30 mm and lever length 90 mm

4)

Spool valve is the type of amplifier used in device SRD960-C

5)

Standard diaphragm amplifier
Devices SRD960-B and SRD960-Cxxxxxxxxxx-M are using "standard"
diaphragm amplifier

Air consumption (steady state) l

n

/h (scfh)

Supply air
pressure
bar (psig)

1.4

(20)

3

(45)

6

(90)

single
acting

80

(2.8)

130

(4.6)

220

(7.8)

double
acting

130

(4.6)

230

(8.1)

430

(15.2)

Spool
Valve

100

(3.5)

240

(8.5)

500

(17.7)

Special Version of SRD960

SRD960 for actuator with rotation up to 300°
This special version of the SRD960 is designed to be

mounted by means of standard attachment kit (like the

EBZG-R) onto rotary actuator with rotation up to 300°.
This special version is made of a standard SRD960 with

new gears.
To be ordered under special version ECEP EP0265