LED Indications:
A steady green LED indicates that this panel is iiiinterlink enabled.
A steady red LED indicates that this panel is iiiinterlink disabled i.e. no address programmed.
The pulsing red LED indicates the programmed address number 1 to 8 of this panel.
The 8 yellow pushbutton LEDs indicate the detection of all connected panels on the iiiinterlink bus, with this
panel's LED rapidly flashing.

Procedure:

• Enter the

iiii

nterlink Code

.

• Allow 5 seconds for scanning - the 8 yellow pushbutton LEDs cycle around.

• Press

to seek the next available address - indicated by a rapid flashing pushbutton LED.

- OR -

• Press

to clear the address and disable this panel's iiiinterlink functionality.

• Press

to accept OR press

to quit without updating the option.

• Allow 8 seconds for the system to stabilise before proceeding with other panel operations.

Note: The panel automatically kicks back to normal standby User Mode after 60s if left unattended.

Removing a Noby-220
iiiiR2 panel from the iiiinterlink bus
A panel may be effectively switched offline by clearing its address as described in the above procedure.