3.3 Process module parameters

Pos : 26 /Anl eitungen/ SPS - Baus tei ne/Pr ozessbaust eine/ Eing angs par ameter [Pr ozessbaust eine] @ 1\ mod_1338299632262_388. doc x @ 26419 @ 3 @ 1

3.3.1 Input parameters

Name

Type

Interfac
e

Description

Module

Prozess_PPO…

…1

_

1

6

…2

_

1

6

…3

_

1

6

…4

_

1

6

…2

_

3

2

…4

_

3

2

PED_FU

INT

IN

Start address of the inputs from the hardware
configurator

X

X

X

X

X

X

PAD_FU

INT

IN

Start address of the outputs from the
hardware configurator

X

X

X

X

X

X

rel_fwd

BOOL

IN

Enables the direction of rotation of the drive
for a CW rotating field

X

X

X

X

X

X

rel_rev

BOOL

IN

Enables the direction of rotation of the drive
for a CCW rotating field

X

X

X

X

X

X

volt_lock

BOOL

IN

0 = The inverter output voltage is switched

off, the FI goes into switch-on block
status.

1 = OFF 2 is cancelled; see manual for

details

X

X

X

X

X

X

fast_stop

BOOL

IN

0 = Quick stop with programmed quick stop

time; with disconnection from supply at
f=0Hz; the FI switches to starting
disabled condition.

1 = OFF 3 is cancelled; see manual for

details

X

X

X

X

X

X

fault_acc

BOOL

IN

With the switch from 0 to 1, inactive errors
are acknowledged. Note: When a digital
input has been programmed for the
"ack.fault" function, this bit must not
permanently be set to 1 via the bus
(otherwise, flank evaluation would be
prevented).

X

X

X

X

X

X

FU_Bus_in8

BOOL

IN

Only for SK 2xxE and SK 5xxE. For further
details of the function please refer to
parameter P480 in the frequency inverter
manual

X

X

X

X

FU_Bus_in9

BOOL

IN

Only for SK 2xxE and SK 5xxE. For further
details of the function please refer to
parameter P480 in the frequency inverter
manual

X

X

X

X

param_set

INT

IN

The required parameter set number is
entered here (1...4).

X

X

X

X

X

X

scal_SP1

REAL

IN

Scales the setpoint entered in parameter
P546 or P546[-01]. This parameter is
multiplied by the value from SP_1.

Example:

A value of 1.0 must be entered order to
communicate a setpoint precisely according
to the bits at input SP_1.

A value of 163.84 must be entered at input
SP_1 in order to communicate a setpoint to
the FI as a percentage.

X

X

X

X

X

X