NORD Drivesystems BU0940 User Manual

Page 32

Advertising
background image

S7 standard modules

– Supplementary manual options for NORD - Frequency Inverters

32

BU 0940 GB-3612

Name

Type

Interfac
e

Description

Module

Prozess_PPO…

…1

_

1

6

…2

_

1

6

…3

_

1

6

…4

_

1

6

…2

_

3

2

…4

_

3

2

scal_SP2

REAL

IN

Scales the setpoint entered in parameter
P547 or P546[-02]. This parameter is
multiplied by the value from SP_2.

Example:

Similar to scal_SP1

X

X

X

X

scal_SP3

REAL

IN

Scales the setpoint entered in parameter
P548 or P546[-03]. This parameter is
multiplied by the value from SP_3.

Example:

Similar to scal_SP1

X

X

SP_1

REAL

IN

Here the setpoint is entered as a 32 bit real
number. A 16 bit value is output to the
frequency inverter.

X

X

X

X

SP_1

REAL

IN

Here the setpoint is entered as a 32 bit real
number. A 32 bit value is output to the
frequency inverter.

X

X

SP_2

REAL

IN

Here the setpoint is entered as a 32 bit real
number. A 16 bit value is output to the
frequency inverter.

X

X

SP_2

REAL

IN

Here the setpoint is entered as a 32 bit real
number. A 32 bit value is output to the
frequency inverter.

X

X

SP_3

REAL

IN

Here the setpoint is entered as a 32 bit real
number. A 16 bit value is output to the
frequency inverter.

X

X

scal_AV1

REAL

IN

Scaling of the actual bus value 1 entered in
parameter P543 or P543[-01]. This value is
multiplied by the contents of parameter P543
or P543[-01].

Example:

A value of 1.0 must be entered order to
communicate a setpoint precisely according
to the bits at output AV_1.

A value of 163.84 must be entered order to
communicate a setpoint as a percentage at
output AV_1.

X

X

X

X

X

X

scal_AV2

REAL

IN

Scaling of the actual bus value 2 entered in
parameter P544 or P543[-02]. This value is
multiplied by the contents of parameter P544
or P543[-02].

Example:

Similar to scal_AV1

X

X

X

X

Advertising