3 Process modules

BU 0940 GB-3612

33

Name

Type

Interfac
e

Description

Module

Prozess_PPO…

…1

_

1

6

…2

_

1

6

…3

_

1

6

…4

_

1

6

…2

_

3

2

…4

_

3

2

scal_AV3

REAL

IN

Scaling of the actual bus value 3 entered in
parameter P545 or P543[-03]. This value is
multiplied by the contents of parameter P545
or P543[-03].

Example:

Similar to scal_AV1

X

X

AV_1

REAL

INOUT

Output of the calculated actual value 1 from
the frequency inverter

(scal_AV1 * actual bus value 1 from the FI)

X

X

X

X

X

X

AV_2

REAL

INOUT

Output of the calculated actual value 2 from
the frequency inverter

(scal_AV2 * actual bus value 2 from the FI)

X

X

X

X

AV_3

REAL

INOUT

Output of the calculated actual value 3 from
the frequency inverter

(scal_AV3 * actual bus value 3 from the FI)

X

X

Table 4: Process modules - Input parameters

Pos : 27 /Anl eitungen/ SPS - Baus tei ne/Pr ozessbaust eine/ Ausgangsparamet er [Pr oz ess baust ei ne] @ 1 \mod_1338370927455_388.doc x @ 26451 @ 3 @ 1

3.3.2 Output parameters

Name

Type

Interfac
e

Description

Module

Prozess_PPO…

…1

_

1

6

…2

_

1

6

…3

_

1

6

…4

_

1

6

…2

_

3

2

…4

_

3

2

ZSW:

WORD

OUT

Status word from the frequency inverter.

X

X

X

X

X

X

ready_start:

BOOL

OUT

Initialisation is complete, the loading relay is
in status ON, the output voltage is still
disabled.

X

X

X

X

X

X

run:

BOOL

OUT

The frequency inverter outputs a 'runnning'
message

X

X

X

X

X

X

fault

BOOL

OUT

Drive malfunctioning and out of order; the
frequency inverter goes to switch-on block
status if acknowledgement is successful. A
new positive flank must be generated at the
enabling output "rel_fwd" or "rel_rev".

X

X

X

X

X

X

warning

BOOL

OUT

The frequency inverter has generated a
warning. The drive remains in operation. An
acknowledgement is not required.

X

X

X

X

X

X

Bus_out10

BOOL

OUT

Only with SK 5xxE. For further details of the
function please refer to parameter P481 in
the frequency inverter manual

X

X

X

X

Bus_out13

BOOL

OUT

Only with SK 5xxE. For further details of the
function please refer to parameter P481 in
the frequency inverter manual

X

X

X

X

actual_para

INT

OUT

Actually used parameter set (1...4)

X

X

X

X

X

X

Table 5: Process modules - Output parameters