4 Electrical connection

Power cable:

Connection to the mains should be carried out with a cable suitable for the local
conditions and with a sufficient wire gauge (max. 4mm

2

).

Aux. Voltage:

24V I/O:

2x 3 phase plug with tension-spring terminals of 2.5mm

2

: voltage supply

and output

Aux. Voltage:

24V bus:

2x 3 phase plug with tension-spring terminals of 2.5mm

2

: voltage supply

and output

Cable entry:

3 x M25 and 2 x M16 are available. The motor startup is realised with a system connector
Harting HAN 10E.

Power output

[Line Out]

Power feed

[Line In]

Functional module

Analogue output 24V

Auxiliary voltage

[24V I/O]

(equal to 24V_Ext.)

Auxiliary voltage

[24V Bus]

In preparation:

functional module

Auxiliary voltage

[24V_Ext.]

(equal to 24V I/O)