4 status leds, 1 external 24v supply – NORD Drivesystems BU0130 User Manual

Page 15

Advertising
background image

NORDAC SK DA-130E

BU 0130 DE

techn. changes reserved

15

4.4 Status LEDs

Above the M12 terminal sockets, status LEDs have been mounted for input and output status. These are
connecting sockets of 24V ext. as well as the I/Os (sensors/actuators).

4.4.1 External 24V supply

For external 24V supply of the I/Os, a connection with an M12 terminal socket is available. Here, a green LED
has been positioned, which shows the status of 24V Ext. or 24V I/O (the same potential).

To recognise the relevant I/O status, orange (signal) status LEDs have been fitted. These stand for each input
(input left) and output (output, right).

Left LED (orange)

Æ Input

Right LED (orange)

Æ Output

M12

terminal

socket

LED

left

LED

right

I/O 1

Digital input 2

Output multi-functional relay 24V

I/O 2

Digital input 3

---

I/O 3

Digital input 4

---

I/O 4

Digital input 5

---

I/O 5

Analogue/ Digital input 1

Analogue/ Digital output 24V

I/O 6

Analogue/ Digital input 2

---

Orange LED

for input signals

Orange LED

for output signals

Green LED

for 24V Ext. or 24V I/O

(same potential)