NORD Drivesystems BU0130 User Manual

Page 14

Advertising
background image

NORDAC SK DA-130E

14

techn. amendments reserved

BU 0130 DE

4.3 M12 terminal sockets

To receive drive actuators and sensors, M12 terminal sockets are
available. The signals received are picked up by the frequency inverter
(standard I/O) and can be used as drive function or can be transmitted
to the optional bus module for controlling tasks.

For the SK 130E, 7 M12 terminal sockets are available. Below is a list of
the functionalities and internal links.

* The analogue/digital output 24V on pin 5 of IO1 is only available if the relevant dip switch has been set to 1.
In the factory setting, this switch is set to ON (

Æ also see p. 15).

M12 terminal

socket

Pin

Function

I/O 1

1

24V I/O

2

Output multi-functional relais
24V

3

GND

4

Digital input 2

5

Analogue/Digital output 24V*

I/O 2

1

24V I/O

2

---

3

GND

4

Digital input 3

5 ---

I/O 3

1 24V

I/O

2 Out

3 GND

4

Digital input 4

5 ---

I/O 4

1 24V

I/O

2 Out

3 GND

4

Digital input 5

5 ---

I/O 5

1 24V

I/O

2

Analogue/Digital output 24V

3 GND

4

Analogue/Digital input 1

5 ---

I/O 6

1 24V

I/O

2 ---

3 GND

4

Analogueue/Digital input 2

5 ---

M12 terminal socket (female),
configuration:

Advertising