Device rs-nagmp / rs-nagmp.1 – NORSTAT Safety Relays User Manual

Page 12

Advertising
background image

DEVICE

RS-NAGMP / RS-NAGMP.1

Emergency stop

APPLICATIONS

and safety gate monitoring relay

APPROVALS

CE, TÜV, (UL, C-UL pending)

CONTACTS

3 normally open safety, 1 normally auxiliary closed

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

With (NAGMP.1) and without (NAGMP) choosable opposite polarity
between channels

LED

Power, Channel 1 and channel 2

24 V AC / DC (without galvanic disconnection, but with a safety

OPERATING VOLTAGE

24 VDC / 12VDC (without galvanic disconnection, but with an electronic

24, 110-127, 230 V AC (with galvanic disconnection/transformer)

POWER CONSUMPTION

ca. 3,5 VA / 24VDC: 1,8W / 12VDC: 1,4W

START UP DELAY / FALLBACK TIME

< 300 ms / < 20 ms

CONTACT CAPACITY max.

8 A, 250 V AC, 250 V DC, normally closed: 24 V AC / DC

CONTACT CAPACITY min. at 24V DC (*)

10 mA

SIMULTANEITY

Simultaneous protective door contacts : ca. 75 ms

ENVIRONMENTAL TEMPERATURE

- 25°C to + 55°C

SWITCHING CAPACITY

2000 VA (resistive load), 200 W

CONTACT SECURITY

6 A quick acting or 4 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

A supply voltage must be applied at the terminals A1 and A2 in order to

operate the device. If this is done there is a voltage of 24V DC at the

terminal T11. Terminals T12, T21, T22 and T23 have to be wired as it is

shown in the application examples. To start the unit terminal T33 has to

bridged with terminal T34 or terminal T34 has to get a 24V DC impulse

(short time bridging of the connection terminals T33-T34). If this is done the

safety-contacts 13-14, 23-24 and 33-34 are closed and 41-42 are open. The

LEDs channel 1 and channel 2 illuminate. Through terminals X1 and X2 the

function of an external contactor can be monitored. Terminals X1 and X2

have to be bridged in order to operate the device.

T21*

T33 T34

Not-Halt

E-Stop

Start

* Klemme T21 nur bei RS-NAGMP.1

T12 T22 T11

* terminal T21 only by RS-NAGMP.1

FUNCTION CIRCUIT DIAGRAM

X2

~~

PE

-

+

=

K1

~~~

R4

~

T1

(+)

A1

(-)

A2

T34

T33

T11

X1

14

K2

K3

Controllogic

34

24

42

13

T12

T22

33

23

41

T21*

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: RS-NAGMP: PLd, Cat.3 / RS-NAGMP.1: PLe, Cat.4

MTTFd: 73,61 years / high, DC: Cat. 3: 90% / medium, Cat. 4: 99% / high

CCF: achieved

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com