Two hand control relays device safe z.2 – NORSTAT Safety Relays User Manual

Page 25

Advertising
background image

Two hand control relays

DEVICE

SAFE Z.2

Two hand control relay

APPLICATIONS

for type I-III c

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

2 normally open safety, 1 normally auxiliary closed, 1 PLC-output

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

Two hand control relay according ZH 1 / 456 and DIN EN 574

LED

Power, channel 1 and channel 2

24 V AC / DC (electronic fuse)

OPERATING VOLTAGE

48, 115, 230 V AC (with galvanic disconnection / transformer)

POWER CONSUMPTION

ca. 2 VA

START UP DELAY / FALLBACK TIME

< 50 ms / < 25 ms

CONTACT CAPACITY max.

6 A, 250 V AC, 24 V DC

CONTACT CAPACITY min. at 24V DC (*)

6 mA

SIMULTANEITY

Simultaneous: 0,5s

ENVIRONMENTAL TEMPERATURE

- 25 °C to + 55 °C

SWITCHING CAPACITY

1500 VA (resistive load)

CONTACT SECURITY

6,3 A quick acting or 4 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

After supply voltage was applied to terminals A1 and A2, the SAFE Z will be

ready for operation. The power LED illuminates. If the button S1 is pressed

and within 0,5 sec. the button S2 also pressed, the outputs 13-14, 23-24

are closed and 31-32 will be opened. The machine will be started. The PLC-

output (34) is connected with 24 V supply voltage. If one or both buttons are

released, the outputs 13-14 and 23-24 open immediately. The output 31-32

closes. Only after releasing of both buttons S1 and S2, a new cycle can be

started. If the time for pressing the buttons S1 and S2 will be longer than 0,5

sec., the outputs were not released. The outputs 13-14 and 23-24 keep

open. The machine cannot be started. On the terminals Y1 and Y2 machine

release circuit (repeating contactor control) or a bridge can be connected.

For version with detachable clamps (screw - or cage clamps) ...

please ask our sales team!

Still available: RS-NAGZ with an additionally auxiliary contact. For further

information please see the manual or www.automation-safety.com

S11

S21

S1

S12

S22

S2

Y1 Y2

Kext

FUNCTION CIRCUIT DIAGRAM

S21

Überwachungslogik

K1

+

-

DC

AC

electr.
fuse

elektr.
Sicherung

A1

A2

control logik

S22 S12

S11

34

14

24

K2

32

Y2

Y1

13

23

31

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 36,45 years / high, DC: 99% / high,

CCF: achieved

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com

Advertising