Device rs-nagx 5 – NORSTAT Safety Relays User Manual

Page 30

Advertising
background image

DEVICE

RS-NAGX 5

Expansion module

APPLICATIONS

for emergency stop relay according to VDE 0113

APPROVALS

CE, TÜV (UL, C-UL pending)

CONTACTS

5 normally open safety and 1 normally safety closed (feedback)

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

Easy way to increase the number of contacts

Compact housing

LED

Channel 1 and channel 2

24 V AC / DC (without galvanic disconnection, but with a safety

OPERATING VOLTAGE

resistor)

POWER CONSUMPTION

ca. 2,4 VA

START UP DELAY / FALLBACK TIME

< 30 ms

CONTACT CAPACITY max.

6 A, 250 V AC, 24 V DC, sum of currents <16 A

CONTACT CAPACITY min. at 24V DC (*)

6 mA

SIMULTANEITY

ENVIRONMENTAL TEMPERATURE

- 25°C to + 55 °C

SWITCHING CAPACITY

1500 VA

CONTACT SECURITY

6 A quick acting or 4 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

Input circuit A1 is to be connected with one of the redundant safety outputs

(13-14). Errors of the expansion unit will be announced over the feedback

control loop (Y1-Y2) and the next activation will be disabled.

In case of protected wiring (short current circuit exclusion) and regularly

tests, for example during maintenance, up to safety category 4.

A1

A2

+24

V

0V

A1

A2

Y1

Y2

X1

X2

z.B. RS-NAGL

e.g. RS-NAGL

RS-NAGX5

13

14

FUNCTION CIRCUIT DIAGRAM

K1

K2

DC

AC

A1 A2

14 24 34 44

54 Y2

13 23 33 43 53 Y1

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 74,2 years / high, DC: 99% / high,

CCF: achieved

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com

Advertising