Muting

DEVICE

RS-NAGU.12

Muting control

APPLICATIONS
APPROVALS

CE, TÜV

CONTACTS

3 electronic safety semiconductor outputs (2 PNP / 1 NPN)

4 muting sensors connectable

SPECIAL CHARACTERISTICS

Control of filament of external muting lamp

Suitable for ESPE-2 with selftest

LED

Power, channel 1, channel 2, fault and restart interlock

OPERATING VOLTAGE

24 V DC

POWER CONSUMPTION

10 W (up to 60 W including peripheral devices)

START UP DELAY / FALLBACK TIME

< 6 ms

CONTACT CAPACITY max.

0,7 - 1,5 A

(*2)

, 24 V DC

CONTACT CAPACITY min. at 24V DC (*)

1 mA

SIMULTANEITY

Simultaneous of the muting sensors : 3 s

ENVIRONMENTAL TEMPERATURE

- 25°C to + 55°C

SWITCHING CAPACITY

17 W

CONTACT SECURITY

outputs are permanently short circuit proof

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

RS-NAGU.12 could be used together with safety light barriers and safety

light curtains with safety category 2 which have a selftest. The RS-NAGU.12

is used for muting of safety light barriers and safety light curtains. So that

material - transport to or from a machine can be done. Applications can be

found in the automotive industry, packaging machines or at highly

automated production systems. The differentiation between human beings

and material flow is done with up to four muting sensors or two safety light

barriers. Inductive sensors or mechanical switches can also be used as

muting sensors. After connection as per application guide, the device will be

ready as soon as the power LED and channel are illuminated. If LED

channel 1 is blinking, a fault exists or a wrong connection has been made.

In ready condition the RS-NAGU.12 can be started by pushing the start

key. If it cannot be started, then at least one of the muting sensors is

blocked or not connected correctly. If a muting sensor is blocked by material

supply, a muting can be initiated by actuation of the key switch. If the light

barrier is interrupted after a muting cycle, RS-NAGU.12 can be activated by

pushing the start key after the failure has been fixed. As soon

as muting sensors 1 and 2, respectively 3 and 4 will be activated within 3

sec.,

the RS-NAGU.12 will initiate a muting cycle. Interruption of the light barrier

will

not cause a stop of the machine. If 3 of the 4 muting sensors are

deactivated,

the muting cycle will end after 0.25 sec.

FUNCTION CIRCUIT DIAGRAM

(*2)

1,5 A permanent output (1 output) up to 4,5 A start-up current

(t<1s, Uv>21,6V),

1 A permanent current (2 outputs), 0,7 A permanent current

(3 outputs)

Notice: please ask for detailed documentation.

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: >100 years / high, DC: 99% / high,

CCF: achieved