DEVICE

RS-NAGV

Emergency stop

APPLICATIONS

and safety gate monitoring relay

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

6 normally open safety, 4 normally auxiliary closed

Opposite polarity between channels

SPECIAL CHARACTERISTICS

Cyclial monitoring of the function

LED indicators for status and supply diagnostic

LED

Channel 1 and channel 2

24 V AC / DC (without galvanic disconnection/ safety resistor)

OPERATING VOLTAGE

24 V DC (without galvanic disconnection / electronic fuse),

24, 110-127, 230 V AC (with galvanic disconnection/transformer)

POWER CONSUMPTION

ca. 6 VA

START UP DELAY / FALLBACK TIME

< 200 ms / ca. 30 ms

CONTACT CAPACITY max.

4 A, 240 V AC, 60 V DC

CONTACT CAPACITY min. at 24V DC (*)

10 mA

SIMULTANEITY

Simultaneous protective door contacts : ca. 75 ms

ENVIRONMENTAL TEMPERATURE

- 25°C to + 55°C

SWITCHING CAPACITY

1000 VA (resistive load), 120 W

CONTACT SECURITY

4 A quick acting

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

A supply voltage must be applied at terminals A1 and A2 in order to operate

the device. If this is done there is a voltage of 24V DC at terminals T11, T12

and T22 must be wired as shown in the application examples. To start the

unit terminal T11 must be bridged with terminal T34 by means of a closing

contact or terminal T34 must receive a 24V DC impulse (short time bridging

of the connection terminals T11-T34). If this is done contacts 13-14, 23-24,

33-34, 43-44, 53-54 and 63-64 close and 71-72, 81-82, 91-92 and 101-102

open. The LEDs channel 1 and channel 2 illuminate. Through terminal X1

and X2 the function of an external contactor can be monitored. Terminals

X1 and X2 must be bridged in order to operate the device.

T34 T11

Not-Halt

E-Stop

Start

T12

T44 T22

Not-Halt

E-Stop

X1 X2

FUNCTION CIRCUIT DIAGRAM

T44

PE

+

-

K1

K3

K2

K3

~

~

T1

R4

A2

(+)

A1

(-)

K1

K2

X2

X1

T11 T34

T22

T12

44

34

14 24

54 64 72

102

82 92

43

33

23

13

53 63 71

101

81 91

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 74,61 years / high, DC: 99% / high

CCF: achieved