NORSTAT Safety Relays User Manual

Page 18

Advertising
background image

Mat-, edges-control relays

DEVICE

RS-NAGA / RS-NAGAO

Emergency stop and safety gate and mat control relay

APPLICATIONS

(the device-system isn´t guide positive for the "start" push button)

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

3 normally open safety, 1 normally auxiliary closed

LED indicators for status ans supply diagnostic

SPECIAL CHARACTERISTICS

Selectable opposite polarity between channels

With (RS-NAGA) and without (RS-NAGAO) start control

LED

Power, channel 1 and channel 2

24 V DC (with electronic fuse)

OPERATING VOLTAGE

24, 48, 110-127, 230 V AC (with galvanic disconnection/transformer)

24 V AC / DC (fuse F1) not useable for safety mats

POWER CONSUMPTION

ca. 3,5 VA, 24 V DC: 2W

START UP DELAY / FALLBACK TIME

< 150 ms / < 50 ms

CONTACT CAPACITY max.

6 A, 250 V AC, 250 V DC

CONTACT CAPACITY min. at 24V DC (*)

10 mA

SIMULTANEITY

Simultaneous protective door contacts : ca.75 ms

ENVIRONMENTAL TEMPERATURE

- 25°C to + 55°C

SWITCHING CAPACITY

1500 VA (resistive load), 100W

CONTACT SECURITY

6 A quick acting (normally open), 4 A time lag (normally closed)

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

A supply voltage must be applied to terminals A1 and A2. Once the supply

voltage is applied, 24V DC is available at terminal S11; power LED

illuminates. Terminals S12, K12 and X1/S22 must be connected according

to the application example selected to meet the application requirements.

To start the unit, terminal X2 and X1/S22 must be bridged. At the variation

"with reset-monitoring" (RS-NAGA) the relay reacts after removing the

bridge X2 to X1/S22. At the variation "without reset-monitoring" (RS-

NAGAO) the function starts after bridging X2 and X1/S22. With all of the

above in place safety contacts 13-14, 23-24, 33-34 closed and 41-42 open.

Channel 1 and channel 2 LEDs illuminate. In series to the reset-button at

terminals X2 and X1/S22 an external device can be monitored.

S12

Not-Halt

E-Stop

X2

S11 S23

X1

S22

FUNCTION CIRCUIT DIAGRAM

K1

X2

Überwachunglogik

monitoring logic

+

~

S23

~~

=

~

A2

T1

A1

F1

S22

S11

X1/

14 24

K2

K2

34 42

S12

K12

23

13

K1

33 41

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat. 4

MTTFd: 73,21 years / high, DC: Cat.4: 99% / high

CCF: achieved

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com