Introduction – Canon CR-2 PLUS AF User Manual

Page 4

Advertising
background image

4

Features

The Canon Digital Retinal Camera CR-2 Plus AF takes digital photographic retinal images of patient’s

eyes across an angle of view of 45 degrees, in a naturally dilated state without using mydriatics. The

CR-2 Plus AF has the following features:

AF (Auto-focus) and AS (Auto-shot) functions

CR-2 Plus AF is equipped with Auto-focus and Auto-shot functions. Those provide significantly

improved ease-of-operation.

A wide range of ISO speed settings

The CR-2 Plus AF can take color images at a wide range of ISO speed settings from ISO 200 up to

ISO 1600 as the standard flash intensity.

In photography at ISO 3200/6400, applying low flash intensity mode can reduce patient discomfort

caused by light glare.

Compact, user-friendly design

The CR-2 Plus AF is designed to be small, lightweight, and compact. This makes it easier to assist

patients.

An operation lever has the integrated functions: vertical movement of the main unit, switching

between anterior segment and fundus, and manual focusing. This lever significantly improves

alignment operability.

Fundus Autofluorescence Photography

(FAF) photography can be performed in non-mydriatic.

Special digital camera

The CR-2 Plus AF is equipped with a special digital camera using EOS digital technology. The

enhanced Canon technology enables the CR-2 Plus AF to fully maximize its capabilities for shooting

high-quality, high-resolution diagnostic images.

Small pupil photography function

The CR-2 Plus AF captures retinal images through pupils of the normal diameters from 4.0 mm.

This small pupil photography function permits image to be captured through pupils from 3.3 mm in

diameters.

System optimized for digital photography

With the supplied imaging control software, the photographed images can be browsed, processed,

stored, output to the DICOM storage server, exported in DICOM or JPEG format and sent to a printer.

In this manual, the operation procedure is described with the Retinal imaging control software NM 2

(referred to as “Rics NM 2”).

Indications for Use

For USA

The CR-2 Plus AF is intended to be used for taking digital images of the retina of the human eye

without a mydriatic. The CR-2 Plus AF has the following photography modes: color, red free and

cobalt digital filter, and fundus autofluorecence (FAF).

For European Union

This medical device is intended to observe and record images of retinal fundus through the pupil

without making contact with subject’s eye for the purpose of diagnosis by way of producing fundus

image information.

1

Introduction