Eco cool - installation manual_l1 v2_ 14, Caution – Electrolux EXI18HL1WE User Manual

Page 14

Advertising
background image

13

Refrigerant pipe connection

Step 5: Installation of Connection Pipe

Copper tube

Flare nut

1 Flaring

work

Main cause for refrigerant leakage is due to
GHIHFWVLQWKHÀDULQJZRUN&DUU\RXWFRUUHFWÀDULQJ
work using the following procedure:

A: Cut the pipes and the cable.

‡ Use the piping kit accessory (if applicable) or

pipes purchased locally.

‡ Measure the distance between the indoor and

the outdoor unit.

‡ Cut the pipes a little longer than the measured

distance.

‡ &XWWKHFDEOHPORQJHUWKDQWKHSLSHOHQJWK

,WLVQRWSRVVLEOHWRSXWWKHPRQDIWHUÀDULQJZRUN

D: Flaring work.

‡ &DUU\RXWÀDULQJZRUNXVLQJÀDULQJWRRODV

shown below.

Handle

Bar

Bar

Yoke

Cone

Pipe

Copper pipe

Clamp handle

Red arrow mark

‡ Firmly hold copper pipe in a die according to

the dimension shown in the table below.

Oblique Roughness Burr

B: Burr removal

‡ Completely remove all burrs from the cut

FURVVVHFWLRQRISLSHWXEH

‡ )DFHWKHHQGRIWKHFRSSHUSLSHWXEHLQD

downward direction as you remove burrs in
order to avoid burrs dropping into the tubing.

E: Check

‡ &RPSDUHWKHÀDUHZRUNZLWKWKHDGMDFHQW

diagram.

‡ If the pipe has any defect, cut off the enlarged

section and redo the work.

Pipe

Smooth all around

Face down

Reamer

,PSURSHUÀDULQJ

Inclined Cracked

Damaged

surface

Uneven

thickness

Even length all

around

&3XWWLQJÀDUHQXWRQ
‡ 5HPRYHÀDUHQXWVDWWDFKHGWRLQGRRUDQG

RXWGRRUXQLWWKHQSXWWKHPRQSLSHWXEH
having completed burr removal.

‡ Make an independent covering for each

pipe with the appropriate tubular isolation.

caution

Outer diam. (mm)

A (mm)

Max. Min.

Ɏ ´ 

1.3

0.7

Ɏ ´

1.6

1.0

Ɏ ´

1.8

1.0

Ɏ ´



2.2

Advertising
This manual is related to the following products: