Eco cool - installation manual_l1 v2_ 23, 22 pump done check after installation – Electrolux EXI18HL1WE User Manual

Page 23

Advertising
background image

22

Pump Done

Check After Installation

When relocating or disposing of the air
conditioner, pump down the system following
the procedure below so that no refrigerant is
released into the atmosphere.

‡ Connect the hose of manifold valve to the

charge port of stop valve on the gas pipe
side of the outdoor unit.

‡ Close the stop valve on the gas pipe side

almost completely.

‡ Fully close the stop valve on the liquid pipe

side.

‡ Turn on the unit in COOL mode.

‡ Fully close the stop valve on the gas pipe

side when the pressure gauge shows
NJIFP

2

 aN3D 

‡ Stop the test run operation by turn the unit

off and all the refrigerant gas have been
collected in the outdoor unit.

Items to be checked

Possible malfunction

+DVWKHXQLWEHHQ¿[HG

¿UPO\"

The unit may drop, shake
or emit noise.

Have you done the
UHIULJHUDQWOHDNDJHWHVW"

,WPD\FDXVHLQVXI¿FLHQW
cooling (heating)

Is thermal insulation
VXI¿FLHQW"

It may cause condensation.

Is water drainage
VDWLVIDFWRU\"

It may cause water
leakage.

Is the voltage in
accordance with the
rated voltage marked on
WKHQDPHSODWH"

It may cause electric
malfunction or damage the
unit.

Is the electric wiring
or piping connection
installed correctly and
VHFXUHO\"

It may cause electric
malfunction or damage the
parts.

Has the unit been

VHFXUHO\HDUWKHG"

It may cause electrical
leakage.

Is the power cord
VSHFL¿HG"

It may cause electric
malfunction or damage the
parts.

Is the inlet or outlet
EORFNHG"

,WPD\FDXVHLQVXI¿FLHQW
cooling (heating)

Is the length of
connection pipes and
refrigerant capacity
UHFRUGHG"

The refrigerant capacity is
not accurate.

Advertising