Eco cool - installation manual_l1 v2_ 6 – Electrolux EXI18HL1WE User Manual

Page 6

Advertising
background image



Installation Site Instruction

7 Select place about 1m or more away from a

TV set or any other electric appliance.

8

6HOHFWDSODFHZKHUHWKH¿OWHUFDQEHHDVLO\
taken out.

9 Do not use the unit in the laundry or by

swimming pool etc.

10 A minimum pipe run of 3 meters is required to

minimize vibration and noise.

11

8VHDVWXG¿QGHUWRORFDWHVWXGVWRSUHYHQW
unnecessary damage to the wall.

12

$Q\YDULDWLRQVLQSLSHOHQJWKZLOOPD\UHTXLUH
adjustment to refrigerant charge.

13 Do not install near a door way.

Outoor Unit

1

6HOHFWDVLWHZKHUHQRLVHDQGRXWÀRZDLU
emitted by unit will not annoy neighbors.

2

6HOHFWDVLWHZKHUHWKHUHLVVXI¿FLHQW
ventilation.

3 Select a site where there is no obstruction

blocking the inlet and outlet.

 The site should be able to withstand the full

weight and vibration of the unit.

 Select a dry place, but do not expose the unit

to direct sunlight or strong wind.

6 Make sure that the outdoor unit is installed in

accordance with the installation instructions,
and is convenient for maintenance and repair.

7 Select a place where it is out of reach of

children and far from animals or plants.

8 Select a place where it is out of reach of

children and far from animals or plants.

9 Select a place where the unit keeps the

horizontal and aligned position.

10 Select at a place that respects the minimum

distances around the outdoor unit as below:

A proper installation site is vital for correct and
HI¿FLHQWRSHUDWLRQRIWKHXQLW

Avoid the following sites where:

‡ VWURQJKHDWVRXUFHVYDSRXUÀDPPDEOHJDV

or volatile liquids are emitted.

‡ high-frequency electro-magnetic waves are

generated by radio equipment, welders or
medical equipment.

‡ salt-laden air prevails (such as close to

coastal areas).

‡ the air is contaminated with industrial vapours

and oils.

‡ the air contains sulphurous gas such as in hot

spring zones.

‡ corrosion or poor air quality exists.

Indoor Unit

1 The air inlet and outlet should be away from

the obstructions. Ensure the air can be blown
through the whole room.

2 Select a site where the condensing water can

be easily drained out, and where it is easily
connected for the outdoor unit.

3 Select a place where it is out of reach of

children.

 Select the place where the wall is strong

enough to withstand the full weight and
vibration of the unit.

 Be sure to leave enough space to allow

access for routine maintenance.

For optimum performance, the indoor unit
should be installed on the wall at a height
PHWHUVRUPRUHDERYHWKHÀRRUEXWOHVV
WKDQPHWHUVIURPWKHÀRRU

6 Make sure that the indoor unit is installed in

accordance with installation dimension as
below:

0RUHWKDQFP FHLOLQJ 

More than
FP

0RUHWKDQP ÀRRU 
/HVVWKDQP ÀRRU 

More than
FP

More than 30cm

More than 30cm

More than 2m

0RUHWKDQFP

Advertising