Gas Leakage Check

Test and Running

Electrical Safety Check

1 Soap water method:

Apply soap water or liquid neutral detergent on
all valves and pipe connections (A, B, C and D,
UHIHUWRWKH¿JXUHEHORZ LQYROYHGLQLQVWDOODWLRQ
by a soft brush to check for leakage.

If bubbles come out, the pipes have leakage.

2 Leak

detector

Use the leak detector to check for leakage.

Perform the electric safe check after completing the
installation:

1 Earthing

work

$IWHU¿QLVKLQJHDUWKLQJZRUNPHDVXUHWKH
earthing resistance by visual detection and
earthing resistance tester.

2 Electrical leakage check

(performing during test running)

'XULQJWHVWRSHUDWLRQDIWHU¿QLVKLQJLQVWDOODWLRQ
the service person can use the electric probe
and multimeter to perform the electrical leakage
check. Turn off the unit immediately if refrigerant
OHDNDJHKDSSHQV&KHFNDQG¿QGRXWWKH
solution ways till the unit operate properly.

Operation Test

1 Before Operation Test

‡ Do not switch on power before installation is

¿QLVKHGFRPSOHWHO\

‡ Electric wiring must be connected correctly

and securely.

‡ Stop valves of the connection pipes should

be fully opened.

‡ All the impurities such as scraps and waste

must be cleared from the unit.

2 Operation Test Method

‡ 6ZLWFKRQSRZHUDQGSUHVV³212))´EXWWRQ

on the remote controller to start the operation.

‡ Press MODE button to select the COOL,

HEAT (if applicable), FAN to check if all the
functions work well.

‡ When the ambient temperature is lower than

ƒ& WKHXQLWFDQQRWEHVHWRQWKHUHPRWH
control to work in COOL mode. Please use
the Emergency Operation mode which is
used only when the remote is unavailable or
in case of maintenance.

Manual control button

Indoor unit
check points

Liquid pipe

Gas pipe

Outdoor
Unit

Outdoor unit
check points

2-way
valve

3-way
valve

Manual control