Eco cool - installation manual_l1 v2_ 17 – Electrolux EXI18HL1WE User Manual

Page 17

Advertising
background image

16

Safety Precautions

Step 9: Electrical Installation

B. In cases where the outdoor unit is

installed below the indoor unit level:

‡ Wrap the piping, drain hose and connecting

cable from the down to up.

‡ Secure the wrapped piping along the exterior

wall using saddle or equivalent.

Electrical safety rules before starting the
installation:

1 A dedicated power supply circuit and breaker

should be provided
for the products which
are not supplied with a
service cord and plug
in accordance with
local electrical safety
regulations.

2 The circuit breaker must have the functions of

magnetic tripping and heat tripping to prevent
short circuit and overload.

3 The appliance shall be installed in accordance

with national wiring regulations.

 A circuit breaker with proper capacity must be

installed according to the table below.

Seal small openings
around piping with a
gum type sealer.

Wrapping

Pipe

Drain hose

Connection
cable

Drain hose

Trap is required to prevent water
from entering into electrical parts.

C. In cases where the outdoor unit is

installed above the indoor unit level:

‡ Wrap the piping and connecting cable from

the down to up.

‡ Form a trap to prevent water from entering

the room.

‡ Secure the wrapped piping along the exterior

wall using saddle or equivalent.

 In case of problems in power supply, the air

conditioner must not be installed before the
FXVWRPHU¿[HVWKHSUREOHP

6 Be sure the power supply matches the air

conditioner.

7 Ensure the live wire, neutral wire and

earth wire in the power socket are properly
connected.

8 Inadequate or incorrect electrical connections

PD\FDXVHHOHFWULFVKRFN¿UHRUVRPH
electrical parts to malfunction.

9 Before performing any electrical work, turn off

the main power to the system.

Earthing Requirements

1 Air conditioner is type I electric appliance. The

unit must be reliably earthed and connected
WRWKHVSHFLDOHDUWKGHYLFHE\WKHTXDOL¿HG
electrician.

Seal small openings
around piping with a
gum type sealer

Trap

Trap

Drain hose

Cooling

Capacity

(BTU)

Circuit

Breaker

Power

Cord

Gauge

Connecting

Cable

Gauge

Fuse Type



10A

>1.0mm

2

>1.0mm

2

$

9000

10A

>1.0mm

2

>1.0mm

2

$

12000

16A

>1.0mm

2

>1.0mm

2

$

18000

$

>

PP

2

>

PP

2

$

Advertising
This manual is related to the following products: