Comfort cool installation manual - l1_ 11, Step 4: installation of indoor unit, Caution – Electrolux EXI12HD1WE User Manual

Page 11

Advertising
background image

11

Connected

Vinyl tape

Tailing 2

Tailing 1

bulge

Flooded

distortion

Do not put the
hose end into
water

'RQRWEORFNZDWHUÀRZ
with a rise.

Step 4: Installation of Indoor Unit

The piping can be output from right, rear right,

left or rear left.

3 Wrap the insulating pipe with wide vinyl tape

to prevent the shift of insulating pipe. Slant
the drain hose downward slightly for smooth
drainage of condensing water.

Insulating pipe

Outlet pipe of

indoor unit

‡ Cut off the tailings 1 when routing the

wiring only.

‡ Cut off the tailings 1 and tailings 2 when

routing both the wiring and piping.

Indoor Unit outline

Connection piping

1 When routing the piping and wiring from the left

or right side of indoor unit, cut off the tailings
IURPWKHFKDVVLVZKHQQHFHVVDU\ VHH¿JXUH
below).

2 The drain hose can be connected at two

different positions. Use the most convenient
SRVWLRQDQGLIQHFHVVDU\H[FKDQJHWKH
position of drain cap and drain hose.

1 The insulating tube should be connected reliably

with the sleeve outside the outlet pipe.

2 The drain hose should be slanted downward

VOLJKWO\ZLWKRXWGLVWRUWLRQEXOJHRUÀXFWXDWLRQ

3 Do not put the outlet in the water.

‡ The drain hose is connected at the

rear left side of the indoor unit when
you receive the product.

Drain hose

(connected at
the rear left side)

Refrigerant
Piping

Drain hole

Drain cap

caution

Advertising
This manual is related to the following products: