Comfort cool installation manual - l1_ 23, Pump done operation test check after installation – Electrolux EXI12HD1WE User Manual

Page 23

Advertising
background image

23

Pump Done

Operation Test

Check After Installation

‡ Connect the hose of manifold valve to the

charge port of stop valve on the gas pipe side of
the outdoor unit.

‡ Close the stop valve on the gas pipe side

almost completely.

‡ Fully close the stop valve on the liquid pipe side.

‡ Turn on the unit in COOL mode.

‡ Fully close the stop valve on the gas pipe side

when the pressure gauge shows 1 - 0.5 kgf/cm

2

(100 ~ 50 kPa).

‡ Stop the test run operation by turn the unit off

and all the refrigerant gas have been collected
in the outdoor unit.

1 Before Operation Test

‡ Do not s witch on power before installation is

¿QLVKHGFRPSOHWHO\

‡ Electric wiring must be connected correctly

and securely.

‡ Stop valves of the connection pipes should

be fully opened.

‡ All the impurities such as scraps and waste

must be cleared from the unit.

2 Operation Test Method

‡ Switch on power and press “ON/OFF” button

on the remote controller to start the operation.

‡ Press MODE button to select the COOL,

HEAT (if applicable), FAN to check if all the
functions work well.

‡ When the ambient temperature is lower than

16°C), the unit can not be set on the remote
control to work in COOL mode. Please use
the Emergency Operation mode which is
used only when the remote is unavailable or
in case of maintenance.

Manual control
button

Manual control button

When relocating or disposing of the air
conditioner, pump down the system following
the procedure below so that no refrigerant is
released into the atmosphere.

Items to be checked

Possible malfunction

+DVWKHXQLWEHHQ¿[HG

¿UPO\"

The unit may drop, shake or
emit noise.

Have you done the
UHIULJHUDQWOHDNDJHWHVW"

,WPD\FDXVHLQVXI¿FLHQW
cooling (heating)

Is thermal insulation
VXI¿FLHQW"

It may cause condensation.

Is water drainage
VDWLVIDFWRU\"

It may cause water leakage.

Is the voltage in
accordance with the
rated voltage marked on
WKHQDPHSODWH"

It may cause electric
malfunction or damage the
unit.

Is the electric wiring
or piping connection
installed correctly and
VHFXUHO\"

It may cause electric
malfunction or damage the
parts.

Has the unit been

VHFXUHO\HDUWKHG"

It may cause electrical
leakage.

Is the power cord
VSHFL¿HG"

It may cause electric
malfunction or damage the
parts.

Is the inlet or outlet
EORFNHG"

,WPD\FDXVHLQVXI¿FLHQW
cooling (heating)

Is the length of
connection pipes and
refrigerant capacity
UHFRUGHG"

The refrigerant capacity is
not accurate.