‡ Both liquid and gas side service valves

on the outdoor unit are kept closed at this
stage.

‡ When relocate the unit to another place,

performevacuation using vacuum pump.

‡ Make sure the refrigerant added into the

air conditioner is in liquid form in any
case.

Air Purging With Vacuum Pump

Caution in Handing
the Stop Valve

Flare nut

Valve body

Charge port

Valve stem

Cap

Stopper

‡ A: Low pressure valve (3-way) - gas side.

‡ B: High pressure valve (2-way) - liquid side.

‡ C and D: they are the ends of indoor unit

connection

Refrigerant

Indoor

Unit

Outdoor

Unit

Lo stop valve
(3-way valve)

Gas side

Liquid side

Hi stop valve
(2-way valve)

Half union

‡ Operation of closing stop valve:

Securely tighten the valve stem with a special
tool. Then securely tighten the valve stem cap
with a spanner or the like.

Step 11:Air Purging and Leakage Test

Air and moisture in the refrigeration system have
undesirable effects as indicated below:

‡ System pressure increase.

‡ Operating current rise.

‡ &RROLQJRUKHDWLQJHI¿FLHQF\GURSV

‡ Moisture in the refrigeration circuit may freeze

and block the capillary tubing.

‡ Water may lead to corrosion of parts in the

refrigeration system.

Therefore, the indoor unit and tubing between
the indoor and outdoor units must be tested
for leakage and evacuated to remove any non-
condensables and moisture from the system.

‡ Preparation

Check that each tube (both liquid and gas
side tubes) between the indoor and outdoor
units have been properly connected and
all wiring for the test has been completed.
Remove the service valve caps from both gas
and liquid sides on the outdoor unit.

‡ For detailed data of pipe length and

refrigerant amount, please refer to page 6.

Refer to the valve cap tightening torque value
as below:

‡ Operation of opening stop valve:

Open the valve stem until it hits against the
stopper. Do not try to open it further.

caution

tips and information

Outer diam.

(mm)

Torque

(N.m)

Additional

Torque (N.m)

Ɏ ´ 

15.7 (1.6kg.m) 19.6 (2.0kg.m)

Ɏ ´

29.4 (3.0kg.m) 34.3 (3.5kg.m)

Ɏ ´

49.0 (5.0kg.m) 53.9 (5.5kg.m)

Ɏ ´

73.6 (7.5kg.m) 78.6 (8.0kg.m)