Comfort cool installation manual - l1_ 8, Installation – Electrolux EXI12HD1WE User Manual

Page 8

Advertising
background image

8

Outdoor Unit Installation

Drain-water
hole

Drain
connecter

Chassis

Hose of inner dia. 16mm
(not provided)

Installation

Air inlet

Air inlet

Air outlet

‡ If a suspended installation is needed,

the installation bracket must allow the
¿[DWLRQDFFRUGLQJWRGLPHQVLRQVRQWKH
¿JXUHDERYH

‡ The wall where the unit will be installed

must be of solid brick, concrete or
provided with other reinforcement ways
WR¿[WKHEUDFNHW7KH¿[DWLRQRIWKH
bracket to the wall and the bracket to
WKHDLUFRQGLWLRQHUPXVWEH¿UPVWHDG\
and leveled.

‡ $QFKRUWKHRXWGRRUXQLWE\¿[LQJWKHKROHV

H[LVWHQWLQLWVEDVHGZLWKEROWVDQGQXWVRI

10 mm tightly (not included).

Place the outdoor unit over a horizontal
concrete or rigid surface (never directly over
grass or land).

Step 2: Outdoor Condensate Drainage

(only for heat pump model)

‡ During heating operation, the condensate and

defrosting water should be drained out reliably
through the drain hose.

‡ Install the outdoor drain connector in the drain-

water hole on the chassis of outdoor unit, and
attach the drain hose to the connector so that
the waste water formed in the outdoor unit can
be drained out.

‡ The drain-water hole must be plugged.

Whether to plug other holes will be determined
by the installer according to actual conditions.

‡ In case of a drain hose, the unit must be

installed on a base more than 3cm height.

Step 1: Securing of Outdoor Unit

Step 1: Installation of Mounting Plate

1 Fit the mounting plate horizontally on the wall

ZLWK¿YHRUPRUHVHOIWDSSLQJVFUHZV W\SH
67[LWHPRQSDJH 

2 Be sure that the mounting plate has been

¿[HG¿UPO\HQRXJKWRZLWKVWDQGDERXWNJ
Meanwhile, the weight should be evenly shared
by every screw.

3 If the wall is made of brick, concrete or the like,

GULOO¿YH  RUPRUHKROHVRIPPGLDPHWHULQ
the wall. Insert clip anchor (item 2 on page 3)
for appropriate mounting screws.

4 The water tray’s outlet for the indoor unit is two-

way drainage design. During installation, the
indoor unit should slightly slant to water tray’s

outlet for smooth drainage of condenser water.

Fit the mounting plate and drill holes in the wall
according to the wall structure and correcponding
mounting points on the mounting plate.
(dimensions are in mm unless otherwise stated)

Cool Capacity (W/h)

Mounting Plate type

2640 A

3520 B

5270 C

6450 D

8210 E

caution

Advertising
This manual is related to the following products: