Comfort cool installation manual - l1_ 19, Installation of outdoor electric wires, Caution – Electrolux EXI12HD1WE User Manual

Page 19: Indoor unit connection

Advertising
background image

19

‡ After tightening the screws, pull the wire

VOLJKWO\WRFRQ¿UPZKHWKHULW¶V¿UPRUQRW

‡ Do not connect two power cables

together to supply power to the air
conditioner.

‡ 'RQRWH[WHQGWKHSRZHUFDEOHFRQGXFWRU

by cutting.

Installation of Outdoor
Electric Wires

Terminal
block

2600~5275W, Heat Pump models

1 Remove the handle on the right side plate of

outdoor unit by loosening the screw.

6450W, Heat Pump models

2 Take off wire cable clamp. Connect and

screw the power connection cable and signal
control wire (for heap pump model only) onto
the terminal block following corresponding
LGHQWL¿FDWLRQQXPEHUVDQGFRORUVRQWKH
terminal blocks of indoor and outdoor units.

3 To prevent water from entering, make a trap

(“U”) in the connection wires (see page 16).

4 Wrap wires that are not connected with

insulating tape so that they do not touch any
electrical or metal parts.

5

)L[WKHSRZHUFRQQHFWLRQZLUHVZLWKZLUH
clamps.

6 Reinstall the handle.

caution

Handle

Handle

yellow-

brown

black

blue

2

N(1)

3

indoor unit connection

green

Handle

yellow-

brown

black

blue

2

N(1)

3

indoor unit connection

green

Handle

Indoor unit connection

yellow-
green

brown

blue black

Handle

Indoor unit connection

yellow-
green

brown

blue black

Advertising
This manual is related to the following products: