Power supply requirements override – HP ROM-Based Setup Utility User Manual

Page 122

Advertising
background image

Power Supply Requirements Override

NOTE:

This option is available on HP ProLiant DL580 G7 and DL585 G7 servers.

The option enables overriding the system requirement that, when one or more x16 high-powered
(225W+) PCI Express graphic cards are installed, the system operate on High Line (200-240
VAC). When this option is enabled, the system is allowed to boot and operate even if the system
is operating on Low Line (100-120 VAC).

CAUTION:

When Power Supply Requirements Override is enabled, some configurations may

not operate properly. Before enabling this option, verify and understand the system power
requirements.

After reading the warning message, press any key to display the following settings”

Default Power Supply Requirements

(default)

Configure for 1 minimum required, 2 required for redundancy

Configure for 2 minimum required, 3 required for redundancy

Configure for 2 minimum required, 4 required for redundancy

Configure for 3 minimum required, 4 required for redundancy

Configure for 4 minimum required, no redundancy

122

RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)

Advertising