Prerequisites for using Linux root credentials

If you have run HP SUM as a root user, remove the temp directory created by HP SUM.

Make sure you have read/write access permissions to the /tmp and /var directories.

If you create a sudo user, make sure that you add that user to the /ect/sudousers file. The
following table shows the privileges and specifications for users.

Specification

Privilege

User

ALL

ALL= (ALL)

Root

ALL

ALL= (ALL)

Sudo_user

Switch update commands

G7 and earlier servers do not support AMS agents. The following tables show what updates occur
when you use the switch agent commands.

NOTE:

To find out if you have any switches installed, use HP SUM to create the Target Firmware

Details Report.

The following table shows what updates occur if no switches are currently installed.

Gen8 servers

G7 and earlier servers

Command

AMS

SNMP

no switches

Nothing

Nothing

/no_mgmt

AMS

Nothing

/use_ams

SNMP

SNMP

/use_snmp

WBEM

WBEM

/use_wmi

AMS and SNMP

SNMP

/use_ams /use_snmp

AMS and WBEM

WBEM

/use_ams /use_wmi

WBEM and SNMP

WBEM and SNMP

/use_wmi /use_snmp

AMS, SNMP, and WBEM

WBEM and SNMP

/use_ams /use_wmi /use_snmp

The following table shows what updates occur if SNMP switches are currently installed.

Gen8 servers

G7 and earlier servers

Command

SNMP

SNMP

no switches

SNMP and AMS

SNMP

/use_ams

SNMP

SNMP

/use_snmp

WBEM and SNMP

WBEM and SNMP

/use_wmi

AMS and SNMP

SNMP

/use_ams /use_snmp

AMS, SNMP, and WBEM

WBEM and SNMP

/use_ams /use_wmi

WBEM and SNMP

WBEM and SNMP

/use_wmi /use_snmp

AMS, SNMP, and WBEM

WBEM and SNMP

/use_ams /use_wmi /use_snmp

Command-line interface