Error Contents

Error Code (SSB2)

Confirm the value immediately below LDEV
Capacity in the Expand Virtual Volumes
window.

Because the shared memory capacity is not
enough to increase the specified capacity, the
operation was rejected.

0xaf2c

Wait until formatting of the specified volume is
finished, or see

“Using Thin Provisioning and

Because the specified THP V-VOL was used by
other software or was being formatted, the
operation was rejected.

0xaf2e

Smart Tiers with other P9500 products” (page
68)

and confirm whether the THP V-VOL is used

with software in which that the THP V-VOL
capacity cannot be increased.

Re-execute the operation after the microcode is
replaced.

Because the THP V-VOL capacity was increased
when the microcode was replaced, the
operation was rejected.

0xaf2f

Re-execute the raidcom extend ldev
command without specifying the -cylinder
option.

Because the raidcom extend ldev
command was executed with specifying the
-cylinder

option to the THP V-VOL for the

open system, the operation was rejected.

0x0b2b

Errors when operating RAID Manager (Data Retention, SSB1:B9BF/B9BD)

Description

Error Code
(SSB2)

The setting failed because the specified volume does not exist.

B9BD

The specified volume is a command device.

B9C2

The command was rejected due to one of the following reasons:

B9C4

The specified volume is a P-VOL or S-VOL of Snapshot.

The specified volume is a virtual volume.

The specified volume is a pool volume.

The specified volume is an S-VOL of Continuous Access Journal.

The specified volume is a journal volume.

The specified volume is reserved for the Auto LUN function.

The specified volume is a P-VOL or S-VOL of Business Copy.

The consumed capacity exceeded the licensed capacity.

The access attribute cannot be changed because the data retention term is set.

The specified volume is a command device.

The specified volume is in the PAIR or COPY status.

The specified volume does not exist.

The S-VOL Disable attribute is set to the specified volume.

The reserve function cannot be canceled using RAID Manager.

Data Retention is not installed.

B9C7

The consumed capacity exceeded the licensed capacity.

B9C9

Either:

B9CA

More than 60 years are set as the data retention days, or.

Another interface updated the settings while Data Retention was changing the settings (Java
conflicted with the other interface).

The retention term cannot be set because the access attribute is read/write.

B9CB

170

Troubleshooting