Management area capacity of an open-systems volume, Capacity of a slot – HP XP P9500 Storage User Manual

Page 49

Advertising
background image

where

the value enclosed in ceil( ) must be rounded up to the nearest whole number.

calculated-management-area-capacity

depends on volume emulation types and

RAID levels (see

“Management area capacity of an open-systems volume” (page 49)

).

To calculate the entire capacity of a CV if the data protection level is set to the Enhanced mode
on the SATA drive:

ceil(entire-capacity-of-a-CV(slots) +
calculated-management-area-capacity)

To convert the resulting entire capacity into blocks:

calculated-entire-capacity-of-a-CV(slots) *
capacity-of-a-slot * 2

where

calculated-entire-capacity-of-a-CV(slots)

means the entire capacity of a CV

if the data protection level is set to the Enhanced mode on the SATA drive.

Management area capacity of an open-systems volume

Management area capacity (KB)

Emulation type

None

OPEN-V

5,760

OPEN-3

19,440

OPEN-8

19,440

OPEN-9

13,680

OPEN-E

Boundary values for RAID levels other than Enhanced mode on SATA drives

Boundary values of external volumes are always one kilobyte, regardless of RAID levels.

Boundary value (KB)

Emulation type

RAID 6 (6D+2P)

RAID 5 (7D+1P)

RAID 5 (3D+1P)

RAID 1 (2D+2D)

2,304

2,688

1,152

768

Other than OPEN-V

3,072

3,584

1,536

1,024

OPEN-V

Boundary values for RAID levels (enhanced data protection level on SATA drives)

A SATA drive supports the OPEN-V emulation type for an open system.

Boundary value (KB)

Emulation type

RAID 6 (6D+2P)

RAID 5 (7D+1P)

RAID 5 (3D+1P)

RAID 1 (2D+2D)

24,576

28,672

6,144

2,048

OPEN-V

Capacity of a slot

Capacity (KB) of a slot

Emulation type

48

Other than OPEN-V

256

OPEN-V